The No. 1 vacuum switching valve assembly (for EGR Bypass Valve) is controlled by the ECM, and the opening and closing of the EGR cooler bypass valve is performed according to the vacuum applied by the vacuum pump.
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Engine switch on (IG) for 3 seconds or more | Open or short in the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) for 3 seconds (1 trip detection logic). | ·
Open or short in No. 1 vacuum switching valve assembly (for EGR Bypass Valve) circuit ·
No. 1 vacuum switching valve assembly (for EGR Bypass Valve) ·
ECM |
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Engine switch on (IG) for 3 seconds or more | Open or short in the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) for 3 seconds (1 trip detection logic). | ·
Open or short in No. 1 vacuum switching valve assembly (for EGR Bypass Valve) circuit ·
No. 1 vacuum switching valve assembly (for EGR Bypass Valve) ·
ECM |
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>REGISTRATION) and initialization (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>INITIALIZATION).
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Inspect the No. 1 vacuum switching valve assembly (for EGR bypass valve) (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>EGR BYPASS VALVE SWITCHING VALVE>INSPECTION).
OK
NG
Disconnect the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C142-1 - Body ground | Engine switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector
(to No. 1 Vacuum Switching Valve Assembly (for EGR Bypass Valve)) |
Reconnect the No. 1 vacuum switching valve (for EGR Bypass Valve) connector.
OK
NG
Disconnect the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C142-2 - C149-16 (ECBV) | Always | Below 1 Ω |
| C142-2 or C149-16 (ECBV) - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) connector.
Reconnect the ECM connector.
OK
NG
Replace the ECM (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECM>REMOVAL).
NEXT
Replace the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>EGR BYPASS VALVE SWITCHING VALVE>REMOVAL).
NEXT
Repair or replace the harness or connector.
If the voltage at the vacuum switching valve assembly (for EGR Bypass Valve) connector is not 11 to 14 V, repair or replace the harness and connector between the No. 1 vacuum switching valve assembly (for EGR Bypass Valve) and No. 1 integration relay.
NEXT
Connect the GTS to the DLC3.
Clear the DTCs (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>DTC CHECK / CLEAR).
Turn the engine switch off wait 30 seconds.
Turn the engine switch on (IG) for 3 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm that the DTC is not output again.
NEXT