The mass air flow meter is a sensor that measures the amount of air flowing through the throttle valve.
The ECM uses this information to determine the fuel injection time and to provide the appropriate air fuel ratio.
Inside the mass air flow meter, there is a heated platinum wire which is exposed to the flow of intake air.
By applying a specific electrical current to the wire, the ECM heats it to a given temperature. The flow of incoming air cools both the wire and an internal thermistor, affecting their resistance. To maintain a constant current value, the ECM varies the voltage applied to the wire and internal thermistor. The voltage level is proportional to the airflow through the sensor, and the ECM uses it to calculate the intake air volume.
The circuit is constructed so that the platinum hot wire and the temperature sensor create a bridge circuit, and the power transistor is controlled so that the potentials of A and B remain equal to maintain the predetermined temperature.
When any of these DTCs are stored, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is calculated by the ECM, according to the engine speed and throttle valve position. The ECM continues operating fail-safe mode until a pass condition is detected.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0102 | The mass air flow meter voltage is below 0.2 V for 3 seconds (1 trip detection logic). | ·
Open or short in mass air flow meter circuit ·
Mass air flow meter ·
ECM |
| P0103 | The mass air flow meter voltage is higher than 4.9 V for 3 seconds (1 trip detection logic). | ·
Open or short in mass air flow meter circuit ·
Mass air flow meter ·
ECM |
When any of these DTCs are output, check the airflow rate by entering the following menus: Powertrain / Engine and ECT / Data List / All Data / MAF.
| Mass Airflow Rate (gm/sec.) | Malfunction |
|---|---|
| Approximately 0.0 | ·
Open in mass air flow meter power source circuit ·
Open or short in VG circuit |
| 160.0 or more | Open in E2G circuit |
If there is a defect in the mass air flow meter or an open or short circuit, the voltage level deviates from the normal operating range. The ECM interprets this deviation as a malfunction in the mass air flow meter and stores a DTC.
Example:
When the sensor output voltage remains below 0.2 V, or higher than 4.9 V, for more than 3 seconds, the ECM stores a DTC.
If the malfunction is not repaired successfully, a DTC is stored 3 seconds after the engine is next started.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Start the engine.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
Read the values displayed on the GTS.
| Mass Airflow Rate (gm/sec.) | Proceed to |
|---|---|
| 0.0 | A |
| 160.0 or more | B |
| Between 1.0 and 160.0* | C |
*: The value must change when the throttle valve is open or closed with the engine running.
A
B
C
Disconnect the mass air flow meter connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C33-3 (+B) - Body ground | Engine switch on (IG) | 11 to 14 V |
| *a | Front view of wire harness connector
(to Mass Air Flow Meter) |
Reconnect the mass air flow meter connector.
OK
NG
Inspect the mass air flow meter (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>MASS AIR FLOW METER>ON-VEHICLE INSPECTION).
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION).
OK
NG
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-5 (VG) - C34-14 (VG) | Always | Below 1 Ω |
| C33-4 (E2G) - C35-18 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-5 (VG) - C35-14 (VG) | Always | Below 1 Ω |
| C33-4 (E2G) - C35-13 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-5 (VG) or C34-14 (VG) - Body ground | Always | 10 kΩ or higher |
| C33-4 (E2G) or C35-18 (E2G) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-5 (VG) or C35-14 (VG) - Body ground | Always | 10 kΩ or higher |
| C33-4 (E2G) or C35-13 (E2G) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
OK
NG
Disconnect the mass air flow meter connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-3 (+B) - 1W-10 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-3 (+B) or 1W-10 - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reinstall the No. 1 integration relay.
OK
NG
Disconnect the mass air flow meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-4 (E2G) - Body ground | Always | Below 1 Ω |
Reconnect the mass air flow meter connector.
for Automatic Transmission
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION).
OK
NG
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-4 (E2G) - C35-18 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-4 (E2G) - C35-13 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-4 (E2G) or C35-18 (E2G) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-4 (E2G) or C35-13 (E2G) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
OK
NG