Home › Engine / Hybrid System › 1GD-FTV (INTAKE / EXHAUST) › WATER PUMP(w/ Urea SCR System) › from 2018.06
RM27T0E _51 Engine / Hybrid System _053680 1GD-FTV INTAKE / EXHAUST _0358838 WATER PUMP(w/ Urea SCR System) A

1GD-FTV INTAKE / EXHAUST  WATER PUMP(w/ Urea SCR System)  INSTALLATION  


PROCEDURE

Hide 161B0 1.INSTALL ELECTRIC WATER PUMP ASSEMBLY

a.

Install the electric water pump assembly with the 2 bolts.

Torque:
7.0 N*m (71 kgf*cm, 62 in.*lbf)


b.

Connect the No. 1 sub-radiator hose and No. 2 sub-radiator hose and attach the 2 hose clamps to secure the hoses.


c.

Connect the connector and attach the 2 wire harness clamps to the electric water pump assembly and fan shroud.