| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P202D7A | Reductant Leakage Fluid Leak or Seal Failure | Either of the following conditions is met:
·
When the rotation of the urea pump is equal to or greater than a fixed value, the pressure sensor value is below a fixed value. ·
When the level sensor value is equal to or greater than a fixed value and the injection accumulation amount is below a fixed value, the level sensor value decreases by a fixed value or greater compared to the last time the level sensor value was acquired. (1 trip detection logic) |
·
Urea tube with heater assembly ·
Urea injector set ·
Urea pump |
Comes on | DTC stored | SAE Code: P202D |
| DTC No. | Data List |
|---|---|
| P202D7A | Reductant Level |
| DTC No. | DTC Detection Drive Pattern |
|---|---|
| P202D7A | Idle the engine for 30 seconds or more |
Wear protective equipment as necessary (protective glasses and gloves).
Do not dilute urea solution.
If urea solution contacts your eyes or skin, immediately wash the contacted area with a large amount of water and consult a doctor as necessary.
If urea solution dries, it deposits a white powder. Also, if urea solution contacts metals such as copper and aluminum for a long period of time, it may promote corrosion. Therefore, if urea solution is spilled, dampen a cloth or other item and wipe it up or rinse the area with cool or warm water.
The urea injector set is a precision instrument. Take necessary precautions for installation and shipping. Do not use the part if it has been struck or dropped.
If the urea solution remaining inside the urea injector set dries out, it may become unable to inject urea solution. Therefore, conduct urea tube with heater assembly installation and removal quickly.
If the urea solution dries out and deposition occurs, urea may cling to the O-ring of the pipe and cause seal problems. Therefore, clean the urea tube with heater assembly and intake port of the urea injector set with water before attaching them.
Perform this procedure in an environment where urea solution will not freeze.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
|---|---|
| DTC P202D7A is output | A |
| DTC P202D7A and other DTCs are output* | B |
*: If any other DTCs (CAN communication malfunctions or open/short circuits) are output, perform troubleshooting for those DTCs first.
A
B
Check around the bottom of the vehicle.
If the urea solution dries on an object, deposition occurs and leaves behind a white powder.
Area to check:
Areas connecting the urea pump and urea injector set.
Perforations in the urea tank sub-assembly.
Connectors not connected properly.
Clogging of the cooling fins of the urea injector set.
If the cooling fins are clogged with foreign matter, remove the foreign matter and clean the cooling fins.
No urea solution leaks.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Pump Check (Backward).
Perform the Active Test.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Purge.
Perform the Active Test.
Perform the Reductant Purge to draw the urea solution back into the urea tank sub-assembly from the urea injector set.
After performing the Active Test, remove the urea injector set from the front exhaust pipe assembly.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL
Do not disconnect the urea injector set from the urea tube with heater assembly.
Use a cover, etc., to prevent foreign matter from entering the exhaust pipe.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Injection Valve.
Perform the Active Test and check for the sound of the urea injector set operating.
Sound of urea injector set operation can be heard (a ticking sound).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Prepare a bucket or other receptacle for collecting urea solution from the urea injector set.
Enter the following menus: Powertrain / Engine / Utility / Reductant Injection Valve Check.
Execute the Reductant Injection Valve Check and check the injection condition of the urea injector set.
This test performs operations from urea solution refueling up to injection.
The pressure inside the pipe may increase during urea solution refueling, intermittently opening the urea injector set and causing urea solution to leak out.
If the urea injector set becomes stuck open during urea solution refueling, once this test starts, intermittent injections will not occur and urea solution will leak out.
Urea solution is intermittently injected by the urea injector set.
3 streams of liquid are sprayed from the urea injector set.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List / Reductant Level.
Check the value of "Reductant Level". If the value of the level is 1, refill the urea solution.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA TANK>REFILL
Refill approximately 3 to 5 L.
Disconnect the urea injector set from the urea tube with heater assembly.
If the urea solution remaining inside the urea injector set dries out, it may become unable to inject urea solution. Therefore, seal the urea injector set with an item such as a cover or rubber cap so that the inside does not dry out.
Prepare a bucket or other receptacle for collecting urea solution from the urea tube with heater assembly.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Discharge / Data List / Diesel Exhaust / Reductant Level.
Execute the Active Test and check the urea solution level.
When the Active Test is executed, urea solution will come out of the urea tube with heater assembly. Collect the urea solution with a bucket or other receptacle.
Urea solution level decreases.
When the level sensor value is stuck, the value does not decrease even when the urea solution is released.
Refill approximately 3 to 5 L of urea solution.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA TANK>REFILL
Urea solution level increases.
When the level sensor value is stuck, the value does not increase even when the urea solution is refilled.
Install the urea injector set.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>INSTALLATION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the urea pump.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA PUMP>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Clear the DTCs.
Turn the engine switch off and wait for at least 30 seconds.
Turn the engine switch on (IG) and turn the GTS on.
Start the engine and wait for 30 minutes or more.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Confirm that the DTC is not output again.
| Proceed to |
|---|
| NEXT |
NEXT
Wash off any matter deposited by the urea solution.
Do not damage the urea injector set when washing it.
Make sure to leave the connector connected when washing to prevent water from entering via the connector.
Sufficiently wipe the area so that no urea solution remains on the flange sealing surface.
After washing, check that 3 streams of liquid are sprayed from the urea injector set.
| Proceed to |
|---|
| NEXT |
NEXT
Replace the urea injector set.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT