Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Urea SCR System) › 2020.08–2021.06
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260461 ECD SYSTEM(w/ Urea SCR System) C

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  P204A12  Reductant Pressure Sensor Circuit High Circuit Short to Battery  P204A14  Reductant Pressure Sensor Circuit Low Circuit Short to Ground or Open  


DESCRIPTION

Refer to DTC P208A14.

Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>P208A14

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P204A12 Reductant Pressure Sensor Circuit High Circuit Short to Battery An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more.
(1 trip detection logic)
·

Open or short in pressure sensor circuit

·

Pressure sensor (urea pump)

·

Urea pump control ECU


Comes on DTC stored SAE Code: P204D
P204A14 Reductant Pressure Sensor Circuit Low Circuit Short to Ground or Open An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more.
(1 trip detection logic)
·

Open or short in pressure sensor circuit

·

Pressure sensor (urea pump)

·

Urea pump control ECU


Comes on DTC stored SAE Code: P204C

Related Data List
DTC No. Data List
P204A12
P204A14
Reductant Pressure

CONFIRMATION DRIVING PATTERN

DTC No. DTC Detection Drive Pattern
P204A12
P204A14
Engine switch on (IG) for 3 seconds

WIRING DIAGRAM

A357972E25
1.323,0.438 1.938,0.635 0.615,0.198 10 false VPSE 1.417,1.031 1.875,1.229 0.458,0.198 10 false PSE 1.344,1.573 1.958,1.771 0.615,0.198 10 false EPSE 1.802,0.573 1.958,0.771 0.156,0.198 10 false 5 1.802,1.135 1.958,1.333 0.156,0.198 10 false 4 1.802,1.677 1.958,1.875 0.156,0.198 10 false 3 0.333,2.042 0.646,2.24 0.313,0.198 10 false s3 0.344,2.229 4.469,2.427 4.125,0.198 10 false Pressure Sensor (Urea Pump) 5.688,0.458 6.302,0.656 0.615,0.198 10 false VCPU 5.708,1.031 6.021,1.229 0.313,0.198 10 false PU 5.708,1.583 6.167,1.781 0.458,0.198 10 false EPU 5.385,0.573 5.698,0.771 0.313,0.198 10 false 57 5.396,1.146 5.708,1.344 0.313,0.198 10 false 56 5.396,1.698 5.708,1.896 0.313,0.198 10 false 55 5.417,2.042 5.729,2.24 0.313,0.198 10 false s4 5.417,2.219 6.979,2.427 1.563,0.208 10 false Urea Pump Control ECU

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.READ VALUE USING GTS (REDUCTANT PRESSURE)
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine / Data List / Diesel Exhaust / Reductant Pressure.


d.

Read the Data List according to the display on the GTS.


Result:
Result Proceed to
-50 kPa A
900 kPa B



A

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

B

8.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)
a.
A360358C23
1.542,0.802 1.885,1.094 0.344,0.292 1.146,2.583 1.635,1.615 true 2.26,2.594 1.792,1.625 true 0.469,0.552 0.781,0.708 0.313,0.156 10 false *a 1.635,0.865 1.948,1.063 0.313,0.198 10 false s3 0.938,2.625 1.552,2.823 0.615,0.198 10 false VPSE 2.125,2.635 2.583,2.833 0.458,0.198 10 false PSE
*a Front view of wire harness connector
(to Urea Pump)


Disconnect the urea pump connector.


b.

Connect terminals 5 (VPSE) and 4 (PSE) of the pressure sensor (urea pump) wire harness side connector.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG) and turn the GTS on.


e.

Enter the following menus: Powertrain / Engine / Data List / Diesel Exhaust / Reductant Pressure.


f.

Read the Data List according to the display on the GTS.

OK:

900 kPa



Result:
Proceed to
OK
NG



OK

3.REPLACE UREA PUMP

NG

5.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - UREA PUMP CONTROL ECU)
3.REPLACE UREA PUMP

Result:
Proceed to
NEXT



NEXT

4.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
4.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Clear the DTCs.


d.

Turn the engine switch off and wait for at least 30 seconds.


e.

Turn the engine switch on (IG) and wait for 3 seconds or more.


f.

Turn the GTS on.


g.

Enter the following menus: Powertrain / Engine / Trouble Codes.


h.

Confirm that the DTC is not output again.


Result:
Proceed to
NEXT



NEXT

END

5.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - UREA PUMP CONTROL ECU)
a.

Disconnect the urea pump connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s3-5 (VPSE) - s4-57 (VCPU) Always Below 1 Ω
s3-4 (PSE) - s4-56 (PU) Always Below 1 Ω
s3-3 (EPSE) - s4-55 (EPU) Always Below 1 Ω
s3-5 (VPSE) or s4-57 (VCPU) - Body ground and other terminals Always 10 kΩ or higher
s3-4 (PSE) or s4-56 (PU) - Body ground and other terminals Always 10 kΩ or higher
s3-3 (EPSE) or s4-55 (EPU) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

6.REPLACE UREA PUMP CONTROL ECU

NG

7.REPAIR OR REPLACE HARNESS OR CONNECTOR
6.REPLACE UREA PUMP CONTROL ECU

Result:
Proceed to
NEXT



NEXT

4.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
7.REPAIR OR REPLACE HARNESS OR CONNECTOR
a.

Repair or replace harness or connector.


Result:
Proceed to
NEXT



NEXT

4.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
8.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
a.

Disconnect the urea pump connector.


b.

Connect the GTS to the DLC3.


c.

Turn the engine switch on (IG) and turn the GTS on.


d.

Enter the following menus: Powertrain / Engine / Data List / Diesel Exhaust / Reductant Pressure.


e.

Read the Data List according to the display on the GTS.

OK:

-50 kPa



Result:
Proceed to
OK
NG



OK

3.REPLACE UREA PUMP

NG

9.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - UREA PUMP CONTROL ECU)
9.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR - UREA PUMP CONTROL ECU)
a.

Disconnect the urea pump connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s3-5 (VPSE) - s4-57 (VCPU) Always Below 1 Ω
s3-4 (PSE) - s4-56 (PU) Always Below 1 Ω
s3-3 (EPSE) - s4-55 (EPU) Always Below 1 Ω
s3-5 (VPSE) or s4-57 (VCPU) - Body ground and other terminals Always 10 kΩ or higher
s3-4 (PSE) or s4-56 (PU) - Body ground and other terminals Always 10 kΩ or higher
s3-3 (EPSE) or s4-55 (EPU) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

6.REPLACE UREA PUMP CONTROL ECU

NG

7.REPAIR OR REPLACE HARNESS OR CONNECTOR