When the engine is started by stop and start control, the engine stop and start ECU controls the starter assembly by activating the ST relay (for starter pinion operation) via voltage from terminal STA and then, using its built-in starter delay circuit, activating the ST NO. 2 relay (for starter motor operation) via voltage from terminal STA2.
If overcurrent is detected in the starter relay circuit, the engine stop and start ECU stores DTC P061519 and blinks the stop and start cancel indicator.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | Memory | Note |
|---|---|---|---|---|---|---|
| P061519 | Starter Relay Circuit Current Above Threshold | Both of the following conditions are met for 1 second (1 trip detection logic):
·
Engine switch on (IG) ·
Overcurrent to ST relay or ST NO. 2 relay is detected. |
·
Wire harness or connector ·
ST relay ·
ST NO. 2 relay ·
Engine stop and start ECU |
Blinks | DTC stored | SAE Code: P0617 |
DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.
CONFIRMATION AFTER TROUBLESHOOTING
If the cable is disconnected from the battery terminal, stop and start control is prohibited until refresh charge is completed.
In this case, let the vehicle idle to complete the refresh charge. The refresh charge is complete when the Data List item "Status of Battery Charge Control" changes from "Refresh Charge Mode". (Usually, idling the engine for 5 to 60 minutes with the battery fluid temperature at 11°C (52°F) or higher, the refresh charge will be completed.)
If the GTS is not available and the Data List item "Status of Battery Charge Control" cannot be checked, charge the battery by idling the engine for approximately 5 to 60 minutes or driving the vehicle, and then drive the vehicle and check that stop and start control operates.
If the engine is started with the hood open, the system determines that a jump start has occurred. Therefore, make sure that the hood is closed before starting the engine and driving the vehicle.
After the refresh charge completes, turn the engine switch off, wait for at least 30 seconds, and then start the engine again. If the vehicle enters refresh charge mode again while the engine is idling, the initial refresh charge did not properly complete, so wait for the refresh charge to complete.
Allow the engine to idle for 3 minutes after it is warmed up and check that the engine idle speed is within 50 rpm of the target idle speed.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Clear the DTCs.
Start the engine and warm it up.
Drive the vehicle at 7 km/h (4.3 mph) or more.
When performing Confirmation Driving Pattern, obey all speed limits and traffic laws.
Depress the brake pedal and stop the vehicle.
Keep the engine stopped by stop and start control for 1 second or more. (Keep the shift lever in D.)
Release the brake pedal with the shift lever in D to start the engine.
Check that DTCs are not output.
STOP AND START SYSTEM OPERATION CHECK
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>OPERATION CHECK
Before replacing the engine stop and start ECU, read the number of starter operations and total number of engine starts and write it into a new engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU, airbag sensor assembly, clear and calibrate the deceleration sensor zero point in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU assembly, perform learning of the external backup boost converter (eco run vehicle converter assembly).
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Inspect the fuses for circuits related to this system before performing the following procedure.
When the engine stop and start ECU or electromagnetic oil pump is replaced, check the electromagnetic oil pump.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Using the GTS, read the freeze frame data before troubleshooting. System condition information is recorded as freeze frame data the moment a DTC is stored. This information can be useful when troubleshooting.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>FREEZE FRAME DATA
DTCs for the stop and start system are not cleared even if the malfunction has been repaired. After repairing the malfunction, be sure to clear the DTCs.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>DTC CHECK / CLEAR
Disconnect the engine stop and start ECU connector.
Remove the BBC NO. 2 and BBC NO. 3 fuses from the No. 7 relay block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G312-1 (BIN2) - BBC NO. 3 fuse terminal 2 | Always | Below 1 Ω |
| G312-3 (BIN1) - BBC NO. 2 fuse terminal 2 | Always | Below 1 Ω |
| G312-1 (BIN2) - Body ground | Always | 10 kΩ or higher |
| G312-3 (BIN1) - Body ground | Always | 10 kΩ or higher |
| BBC NO. 3 fuse terminal 2 - Body ground | Always | 10 kΩ or higher |
| BBC NO. 2 fuse terminal 2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the engine stop and start ECU connectors.
Remove the ST and ST NO. 2 relays from the engine room relay block and junction block assembly.
Remove the BBC NO. 2 and BBC NO. 3 fuses from the No. 7 relay block assembly.
Disconnect the certification ECU (smart key ECU assembly) connector.
Disconnect the park/neutral position switch assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G313-21 (STA) - ST relay terminal 2 | Always | Below 1 Ω |
| G313-23 (STA2) - ST NO. 2 relay terminal 2 | Always | Below 1 Ω |
| G313-21 (STA) - Body ground | Always | 10 kΩ or higher |
| ST relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| G313-23 (STA2) - Body ground | Always | 10 kΩ or higher |
| ST NO. 2 relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| G312-1 (BIN2) - G313-21 (STA) | Always | 10 kΩ or higher |
| G312-3 (BIN1) - G313-21 (STA) | Always | 10 kΩ or higher |
| G312-1 (BIN2) - G313-23 (STA2) | Always | 10 kΩ or higher |
| G312-3 (BIN1) - G313-23 (STA2) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the engine stop and start ECU connector.
| *a | Component without harness connected
(Engine Stop and Start ECU) |
- | - |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G313-21 (STA) - G313-6 (DGND) | Always | 10 kΩ or higher |
| G313-23 (STA2) - G313-6 (DGND) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the ST relay.
Click hereEngine / Hybrid System>1GD-FTV (STARTING)>RELAY>ON-VEHICLE INSPECTION
Inspect the ST NO. 2 relay.
Click hereEngine / Hybrid System>1GD-FTV (STARTING)>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
NG