Stop and start control can be disabled by pressing the stop and start system cancel switch (eco run cancel switch assembly). The stop and start system cancel switch (eco run cancel switch assembly) is a momentary-type switch that switches between on and off when the switch is pressed. While stop and start control is disabled, the stop and start cancel indicator light is illuminated to inform the driver.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Cancel Switch.
Read the value when the stop and start system cancel switch (eco run cancel switch assembly) is pressed.
| Tester Display | Condition | Normal Condition |
|---|---|---|
| Cancel Switch | Stop and start system cancel switch (eco run cancel switch assembly) is pressed | ON |
| Stop and start system cancel switch (eco run cancel switch assembly) is not pressed | OFF |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the stop and start system cancel switch (eco run cancel switch assembly).
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY>REMOVAL
Disconnect the stop and start system cancel switch (eco run cancel switch assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G311-3 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the engine stop and start ECU connector.
Disconnect the stop and start system cancel switch (eco run cancel switch assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G314-5 (ECAN) - G311-4 (ECU) | Always | Below 1 Ω |
| G314-5 (ECAN) - Body ground | Always | 10 kΩ or higher |
| G311-4 (ECU) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG