Home › Power Source / Network › 5L-E (BATTERY / CHARGING) › GENERATOR › from 2020.08
RM27T0E _57 Power Source / Network _053723 5L-E BATTERY / CHARGING _0261017 GENERATOR A

5L-E BATTERY / CHARGING  GENERATOR  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed, installed or replaced during the generator assembly removal/installation are shown below.

Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Battery terminal is disconnected/reconnected Correction of steering angle neutral point Multi-terrain monitor system (Click here)

HINT:

When the cable is disconnected/reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.

Learning completes when vehicle is driven

Effect/Inoperative Function When Necessary Procedures are not Performed Necessary Procedures Link
Lane departure alert system Drive the vehicle straight ahead at 40 km/h (25 mph) or more for 10 seconds or more. (Click here)
Pre-collision system
Lighting system (EXT) (for LED Headlight)
Stop and start system Drive the vehicle until stop and start control is permitted (approximately 5 to 60 minutes) (Click here)
Vehicle stability control system (for Hydraulic brake booster) Drive the vehicle straight ahead at 40 km/h (25 mph) or more for at least 10 seconds. (Click here)


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 16361A 3.REMOVE FAN AND GENERATOR V BELT

Hide 88320 4.DISCONNECT COOLER COMPRESSOR ASSEMBLY

Hide 27020 5.REMOVE GENERATOR ASSEMBLY

a.
A224320

Remove the terminal cap.


b.

Remove the nut and generator wire.


c.

Disconnect the generator connector.


d.
A224321

Disconnect the vacuum pump hose.


e.

Remove the union bolt to disconnect the vacuum pump oil inlet hose and remove the 2 gaskets.


f.

Detach the vacuum pump oil inlet hose from the cord clip.


g.

Disconnect the vacuum pump oil outlet hose.


h.
A224322

Remove the 2 bolts and generator.