The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed, installed or replaced during the generator assembly removal/installation are shown below.
When the cable is disconnected/reconnected to the auxiliary battery terminal, systems temporarily stop operating. However, each system has a function that completes learning the first time the system is used.
Learning completes when vehicle is driven
1. PRECAUTION
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
16361A
3.REMOVE FAN AND GENERATOR V BELT
88320
4.DISCONNECT COOLER COMPRESSOR ASSEMBLY
27020
5.REMOVE GENERATOR ASSEMBLY
Remove the terminal cap.
Remove the nut and generator wire.
Disconnect the generator connector.
Disconnect the vacuum pump hose.
Remove the union bolt to disconnect the vacuum pump oil inlet hose and remove the 2 gaskets.
Detach the vacuum pump oil inlet hose from the cord clip.
Disconnect the vacuum pump oil outlet hose.
Remove the 2 bolts and generator.