Home › Power Source / Network › 5L-E (BATTERY / CHARGING) › GENERATOR › from 2020.08
RM27T0E _57 Power Source / Network _053723 5L-E BATTERY / CHARGING _0261017 GENERATOR A

5L-E BATTERY / CHARGING  GENERATOR  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.

Temporarily install the generator with the 2 bolts.


b.

Connect the vacuum pump oil outlet hose.


c.

Install 2 new gaskets and the vacuum pump oil inlet hose with the union bolt.

Torque:
14 N*m (140 kgf*cm, 10 ft.*lbf)


d.

Connect the vacuum pump hose.


e.

Attach the vacuum pump oil inlet hose to the cord clip.


f.

Install the generator wire with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


g.

Install the terminal cap.


h.

Connect the generator connector.


Hide 88320 2.CONNECT COOLER COMPRESSOR ASSEMBLY

Hide 16361A 3.INSTALL FAN AND GENERATOR V BELT

Hide 4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 5. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART