77830A
1.REMOVE UREA TANK CAP ASSEMBLY
51226A
2.REMOVE FRONT SUSPENSION MEMBER BRACKET LH
82169
3.DISCONNECT NO. 3 FRAME WIRE
Raise the lever while pushing the lock on the lever and disconnect the 2 connectors from the urea pump.
After disconnecting a connector, make sure that dirt, water and other foreign matter does not contact the connector.
Put the urea pump connector ends in plastic bags to prevent damage and foreign matter contamination.
77840
4.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY
Check for dirt or mud on the urea pump and around the urea tube with heater connector before disconnection. Clean if necessary.
Detach the 2 clamps and disconnect the urea tube with the heater assembly from the urea tank sub-assembly.
Disconnect the connector from the No. 3 frame wire.
Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.
Be sure to disconnect the urea tube connector by hand.
Check for foreign matter in the urea pump and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube connector.
Put the urea pump and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.
77871A
5.REMOVE UREA PUMP
| *a | 09809-36010 |
| *b | 09809-60010 (09809-60020) |
| *c | 09809-60010 (09809-60030) |
Install SST (09809-60010) to SST (09809-36010) as shown in the illustration.
| *a | 09808-14031 |
Install SST (09808-14031) to SST (09809-36010).
| *a | Lock Plate |
| *b | Cutout |
Align the SST (09809-60030) with the cutout of the lock plate.
Loosens the lock plate.
Do not use any tools other than SST, such as screwdriver, etc.
Make sure to rotate SST (handle) horizontally. If it is rotated at an angle, SST may come off.
Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.
Remove the urea pump and then drain urea solution (AdBlue) into the container.
Remove the gasket.