Home › Engine / Hybrid System › 1GD-FTV (EMISSION CONTROL) › UREA PUMP › from 2021.06
RM27T0E _51 Engine / Hybrid System _053675 1GD-FTV EMISSION CONTROL _0260631 UREA PUMP A

1GD-FTV EMISSION CONTROL  UREA PUMP  REMOVAL  


PROCEDURE

Hide 77830A 1.REMOVE UREA TANK CAP ASSEMBLY

Hide 82169 3.DISCONNECT NO. 3 FRAME WIRE

a.
A492911

Raise the lever while pushing the lock on the lever and disconnect the 2 connectors from the urea pump.

NOTICE:
·

After disconnecting a connector, make sure that dirt, water and other foreign matter does not contact the connector.

·

Put the urea pump connector ends in plastic bags to prevent damage and foreign matter contamination.




Hide 77840 4.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube with heater connector before disconnection. Clean if necessary.


a.
A462611

Detach the 2 clamps and disconnect the urea tube with the heater assembly from the urea tank sub-assembly.


b.
A492912

Disconnect the connector from the No. 3 frame wire.


c.

Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tube connector by hand.

·

Check for foreign matter in the urea pump and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube connector.

·

Put the urea pump and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.




Hide 77871A 5.REMOVE UREA PUMP

a.
A492913C01
2.5,1.333 2.75,1.5 2.75,1.5 2.917,1.5 true 0.583,1.667 0.75,1.667 0.75,1.667 1.073,1.406 true 0.802,0.167 0.938,0.167 0.938,0.167 1.635,0.5 true 2.594,0.625 2.844,0.333 2.844,0.333 3.01,0.333 true 0.583,0.104 0.833,0.271 0.25,0.167 10 false *c 0.333,1.583 0.583,1.75 0.25,0.167 10 false *b 3,1.417 3.25,1.583 0.25,0.167 10 false *b 3.094,0.26 3.344,0.427 0.25,0.167 10 false *a
*a 09809-36010
*b 09809-60010 (09809-60020)
*c 09809-60010 (09809-60030)


Install SST (09809-60010) to SST (09809-36010) as shown in the illustration.

SST
09809-36010  (09809-03010, 09809-03030, 09809-03040, 09809-03050)
09809-60010  (09809-60020, 09809-60030)


b.
A492914C01
1,0.75 0.833,0.5 0.833,0.5 0.667,0.5 false 0.417,0.417 0.667,0.583 0.25,0.167 10 false *a
*a 09808-14031


Install SST (09808-14031) to SST (09809-36010).

SST
09808-14031  (09808-01010)


c.
A492915C01
2.333,1 2.583,0.75 2.583,0.75 2.75,0.75 true 2.75,0.667 3,0.833 0.25,0.167 10 true *a 1.833,4.333 2.083,4.5 0.25,0.167 10 true *b
*a Lock Plate
*b Cutout


Align the SST (09809-60030) with the cutout of the lock plate.


d.

Loosens the lock plate.

NOTICE:
·

Do not use any tools other than SST, such as screwdriver, etc.

·

Make sure to rotate SST (handle) horizontally. If it is rotated at an angle, SST may come off.

·

Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.




e.
A492916

Remove the urea pump and then drain urea solution (AdBlue) into the container.


f.
A492917

Remove the gasket.