INSPECTION
Inspection · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
| INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
6.9 to 7.9 Ω
Connect the positive (+) lead of the battery to terminal 1 and the negative (-) lead to terminal 2, and check the movement of the valve.

- OK:
Tester Connection
Condition
Specified Condition
1 - 2
Battery positive (+) voltage is applied
Valve moves in direction of left arrow shown in the illustration
Battery positive (+) voltage is cut off
Valve moves in direction of right arrow shown in the illustration
If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may be output.