P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Also covers:
- P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The Automatic Transmission Fluid (ATF) temperature sensor converts the fluid temperature into a resistance value which is input into the ECM.

The ECM applies voltage to the temperature sensor through the ECM terminal THO1.
The sensor resistance changes with the transmission fluid temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The ECM calculates the fluid temperature based on the voltage signal.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| P0712 |
The No. 1 ATF temperature sensor resistance is below 79 Ω for 0.5 seconds or more (1 trip detection logic). |
|
| P0713 |
The No. 1 ATF temperature sensor resistance is higher than 156 kΩ for 0.5 seconds or more, and one of the following conditions is met (1 trip detection logic). Condition A: 15 minutes or more have elapsed. Condition B: If the conditions needed to detect DTC P0711 have been met, P0713 can be detected immediately following engine start. |
|
MONITOR DESCRIPTION
These DTCs indicate an open or short in the Automatic Transmission Fluid (ATF) temperature sensor circuit. The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is below 79 Ω*1 or higher than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM will turn on the MIL and store the DTC.- HINT:
- The ATF temperature can be checked on the intelligent tester display.
- *1: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.
- *2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.
- The ATF temperature can be checked on the intelligent tester display.
WIRING DIAGRAM


INSPECTION PROCEDURE
| DATA LIST |
- HINT:
- Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
- NOTICE:
- In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / ECT / Data List.
According to the display on the tester, read the Data List.
ECT Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
A/T Oil Temperature 1
No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F)
Max.: 215°C (419°F)
- After stall test: Approximately 80°C (176°F)
- With engine cold: Equal to ambient temperature
If the value is -40°C (-40°F) or 215°C (419°F), the No. 1 ATF temperature sensor circuit is open or shorted.
- HINT:
- When DTC P0712 is stored and the intelligent tester output is 150°C (302°F) or higher, there is a short circuit.
- When DTC P0713 is stored and the intelligent tester output is -40°C (-40°F), there is an open circuit.
- Check the temperature displayed on the tester in order to check if a malfunction exists.
If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately stored (in 0.5 seconds). When P0713 is stored, P0711 cannot be stored. It is not necessary to inspect the circuit when P0711 is stored.Temperature Displayed
Malfunction
-40°C (-40°F)
Open circuit
150°C (302°F) or higher
Short circuit
- After stall test: Approximately 80°C (176°F)
| 1. INSPECT NO. 1 TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR) |
Disconnect the C34 No. 1 transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (OT1-) - 9 (OT1+)
Always
79 Ω to 156 kΩ
1 (OT1-) - Body ground
Always
10 kΩ or higher
9 (OT1+) - Body ground
Always
10 kΩ or higher
- HINT:
- If the resistance is out of the specified range of one of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
- Resistance (Reference):
ATF Temperature
Specified Condition
10°C (50°F)
5 to 8 kΩ
25°C (77°F)
2.5 to 4.5 kΩ
110°C (230°F)
0.22 to 0.28 kΩ
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM) |
Disconnect the C45 ECM connector (for LHD).

Disconnect the C46 ECM connector (for RHD).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
C45-123 (THO1) - C45-122 (ETHA)
Always
79 Ω to 156 kΩ
C45-123 (THO1) - Body ground
Always
10 kΩ or higher
C45-122 (ETHA) - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
C46-123 (THO1) - C46-122 (ETHA)
Always
79 Ω to 156 kΩ
C46-123 (THO1) - Body ground
Always
10 kΩ or higher
C46-122 (ETHA) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||