2011-2013 Land Cruiser · Service Manual Drivetrain

P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

The amount of current flow to the solenoid is controlled by the duty ratio* of the ECM output signal. During the lock-up operation, if the duty ratio increases, the lock-up hydraulic pressure increases.
C161168E01
*: The duty ratio is the ratio of the current ON time (A) to the total of the current ON and OFF time (A + B).
Duty Ratio (%) = A / (A + B) x 100
DTC Code
DTC Detection Condition
Trouble Area
P2759
An open or short is detected in the shift solenoid valve SLU circuit for 1 sec. or more while driving (1 trip detection logic).
  1. Open or short in shift solenoid valve SLU circuit
  2. Shift solenoid valve SLU
  3. ECM
Reference: Inspect using an oscilloscope.
Check the waveform of the ECM connector.

Standard:
for LHD 
Terminal No. (Symbol)
Tool Setting
Condition
Specified Condition
C45-15 (SLU+) - C45-14 (SLU-)
5 V/DIV., 1 msec./DIV.
5th (lock-up) or 6th (lock-up) gear
Refer to illustration
for RHD 
Terminal No. (Symbol)
Tool Setting
Condition
Specified Condition
C46-15 (SLU+) - C46-14 (SLU-)
5 V/DIV., 1 msec./DIV.
5th (lock-up) or 6th (lock-up) gear
Refer to illustration

C175012E01

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store this DTC.

WIRING DIAGRAM

C178085E09

INSPECTION PROCEDURE


1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)

  1. C159421E15
    Disconnect the C34 No. 1 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    12 (SLU+) - 4 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    12 (SLU+) - Body ground
    Always
    10 kΩ or higher
    4 (SLU-) - Body ground
    Always
    10 kΩ or higher



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
C177486E28
  1. Disconnect the C45 ECM connector (for LHD).

  1. Disconnect the C46 ECM connector (for RHD).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C45-15 (SLU+) - C45-14 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    C45-15 (SLU+) - Body ground
    Always
    10 kΩ or higher
    C45-14 (SLU-) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C46-15 (SLU+) - C46-14 (SLU-)
    20°C (68°F)
    5.0 to 5.6 Ω
    C46-15 (SLU+) - Body ground
    Always
    10 kΩ or higher
    C46-14 (SLU-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

3. INSPECT SHIFT SOLENOID VALVE SLU
C162477E02
  1. Remove the shift solenoid valve SLU.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise



NG
REPLACE SHIFT SOLENOID VALVE SLU (Click here)
OK

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE (Click here)


← P2757 Torque Converter Clutch Pressure Control Solenoid Performance (Shift Solenoid Valve SLU) (from Jan 2012)P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) (from Jan 2012) →