P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built from Jan 2012
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
Refer to DTC P0894 (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P2716 |
Conditions (a) or (b) below are detected for 1 sec. or more (1 trip detection logic). (a) SLT - terminal: 0 V (b) SLT - terminal: 12 V |
|
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
Disconnect the No. 1 transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
13 (SLT+) - 5 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
13 (SLT+) - Body ground
Always
10 kΩ or higher
5 (SLT-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM) |
![]() ![]() |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
C45-11 (SLT+) - C45-10 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
C45-11 (SLT+) - Body ground
Always
10 kΩ or higher
C45-10 (SLT-) - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
C46-11 (SLT+) - C46-10 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
C46-11 (SLT+) - Body ground
Always
10 kΩ or higher
C46-10 (SLT-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLT |
![]() ![]() |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 2
|
|
||||
| OK | ||
| ||