2011-2013 Land Cruiser · Service Manual Drivetrain

P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

Refer to DTC P0894 (Click here).
DTC Code
DTC Detection Condition
Trouble Area
P2716
Conditions (a) or (b) below are detected for 1 sec. or more (1 trip detection logic).
(a) SLT - terminal: 0 V
(b) SLT - terminal: 12 V
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM
Reference: Inspect using an oscilloscope.
Check the waveform of the ECM connector.

Standard:
for LHD 
Terminal No. (Symbol)
Tool Setting
Condition
Specified Condition
C45-11 (SLT+) - C45-10 (SLT-)
5 V/DIV., 1 msec./DIV.
Engine idling
Refer to illustration
for RHD 
Terminal No. (Symbol)
Tool Setting
Condition
Specified Condition
C46-11 (SLT+) - C46-10 (SLT-)
5 V/DIV., 1 msec./DIV.
Engine idling
Refer to illustration

C175011E01

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C178085E08

INSPECTION PROCEDURE


1. INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)

  1. C159421E14
    Disconnect the C34 No. 1 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    13 (SLT+) - 5 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    13 (SLT+) - Body ground
    Always
    10 kΩ or higher
    5 (SLT-) - Body ground
    Always
    10 kΩ or higher



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
C177486E25
  1. Disconnect the C45 ECM connector (for LHD).

  1. Disconnect the C46 ECM connector (for RHD).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C45-11 (SLT+) - C45-10 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    C45-11 (SLT+) - Body ground
    Always
    10 kΩ or higher
    C45-10 (SLT-) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C46-11 (SLT+) - C46-10 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    C46-11 (SLT+) - Body ground
    Always
    10 kΩ or higher
    C46-10 (SLT-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

3. INSPECT SHIFT SOLENOID VALVE SLT
C162477E01
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 2
    2. Battery negative (-) → Terminal 1
    Valve moves and makes an operating noise



NG
REPLACE SHIFT SOLENOID VALVE SLT (Click here)
OK

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE (Click here)


← P0985 Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR) (+ P0986) (from Jan 2012)P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) (from Jan 2012) →