2011-2013 Land Cruiser · Service Manual Drivetrain

P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

Shifting from 1st to 5th is performed in combination with the "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, S1, S2 and SR which are controlled by the ECM. If an open or short circuit occurs in one of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Click here).
DTC Code
DTC Detection Condition
Trouble Area
P0778
  1. The ECM detects an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears (1 trip detection logic).
  2. The output signal duty is 100%.

HINT:
The SL2 output signal duty is less than 100% under normal conditions.

  1. Open or short in shift solenoid valve SL2 circuit
  2. Shift solenoid valve SL2
  3. ECM

MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. The ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit).
While driving and shifting gears, if the ECM detects an open or short in the shift solenoid valve SL2 circuit, the ECM determines there is a malfunction (Click here).

WIRING DIAGRAM

C161203E26

INSPECTION PROCEDURE


HINT:
The shift solenoid valve SL2 turns ON/OFF normally when the shift lever is in D.
ECM gear shift command
1st
2nd
3rd
4th
5th
Shift solenoid valve SL2
ON
ON
ON
ON
OFF


1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2)

  1. C159421E03
    Disconnect the C34 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    11 (SL2+) - 3 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω
    11 (SL2+) - Body ground
    Always
    10 kΩ or higher
    3 (SL2-) - Body ground
    Always
    10 kΩ or higher



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

  1. C159422E53
    Disconnect the C45 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C45-14 (SL2+) - C45-15 (SL2-)
    20°C (68°F)
    5.0 to 5.6 Ω
    C45-14 (SL2+) - Body ground
    Always
    10 kΩ or higher
    C45-15 (SL2-) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

3. INSPECT SHIFT SOLENOID VALVE SL2

  1. C151311E17
    Remove the shift solenoid valve SL2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

    OK:
    Measurement Condition
    Specified Condition
    1. Battery positive (+) with a 21 W bulb → Terminal 1
    2. Battery negative (-) → Terminal 2
    Valve moves and makes an operating noise



NG
REPLACE SHIFT SOLENOID VALVE SL2 (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)


← P0776 Pressure Control Solenoid "B" Performance (Shift Solenoid Valve SL2) (from Jan 2012)P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2) (from Jan 2012) →