P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2)
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
Shifting from 1st to 6th is performed in combination with the ON and OFF operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely (Click here).| DTC Code |
DTC Detection Condition |
Trouble Area |
| P0778 |
The ECM checks for an open or short in the shift solenoid valve SL2 circuit while driving and shifting gears (1 trip detection logic). The output signal duty ratio equals 100% (the SL2 output signal duty ratio is less than 100% under normal conditions). |
|
Check the waveform of the ECM connector.
- Standard:
for LHD Terminal No. (Symbol)
Tool Setting
Condition
Specified Condition
C45-17 (SL2+) - C45-16 (SL2-)
5 V/DIV., 1 msec./DIV.
Engine idling
Refer to illustration
for RHD Terminal No. (Symbol)
Tool Setting
Condition
Specified Condition
C46-17 (SL2+) - C46-16 (SL2-)
5 V/DIV., 1 msec./DIV.
Engine idling
Refer to illustration


MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL2 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM performs the fail-safe function and turns the other normally functioning shift solenoid valves ON/OFF. In case of an open or short circuit, the ECM stops sending current to the open or short circuited solenoid.While driving and shifting gears, if the ECM detects an open or short in the shift solenoid valve SL2 circuit, the ECM determines there is a malfunction (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- The shift solenoid valve SL2 is turned ON/OFF normally when the shift lever is in D:
ECM gear shift command
1st
2nd
3rd
4th
5th
6th
Shift solenoid valve SL2
ON
ON
ON
ON
OFF
OFF
| 1. INSPECT NO. 2 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2) |
Disconnect the C96 No. 2 transmission wire connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
2 (SL2+) - 4 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
2 (SL2+) - Body ground
Always
10 kΩ or higher
4 (SL2-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (NO. 2 TRANSMISSION WIRE - ECM) |
![]() ![]() |
Disconnect the C45 ECM connector (for LHD).
Disconnect the C46 ECM connector (for RHD).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
C45-17 (SL2+) - C45-16 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
C45-17 (SL2+) - Body ground
Always
10 kΩ or higher
C45-16 (SL2-) - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
C46-17 (SL2+) - C46-16 (SL2-)
20°C (68°F)
5.0 to 5.6 Ω
C46-17 (SL2+) - Body ground
Always
10 kΩ or higher
C46-16 (SL2-) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SL2 |
![]() ![]() |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
Specified Condition
- Battery positive (+) with a 21 W bulb → Terminal 1
- Battery negative (-) → Terminal 2
Valve moves and makes an operating noise
- Battery positive (+) with a 21 W bulb → Terminal 1
|
|
||||
| OK | ||
| ||