B2002 Open in Seat Belt Motor RH Circuit
Diagnostic trouble codes · Vehicles built from Jan 2012
Also covers:
- B2007 Open in Seat Belt Motor LH Circuit
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The seat belt control ECU receives information from the master cylinder solenoid (skid control ECU) via the CAN communication line and tightens the seat belt by operating the motor in the front seat outer belt assembly RH or LH.| DTC Code |
DTC Detection Condition |
Trouble Area |
| B2002 |
Open in the seat belt motor RH circuit continues for 1 second or more. |
|
| B2007 |
Open in the seat belt motor LH circuit continues for 1 second or more. |
|
WIRING DIAGRAM




INSPECTION PROCEDURE
- CAUTION:
- The pretensioner is built into the front seat outer belt assembly. Be sure to follow the correct inspection procedure, as failure to follow the correct procedure (such as inspection of incorrect connectors) may deploy the pretensioner.
| 1. INSPECT SEAT BELT CONTROL ECU |
Disconnect the E41 seat belt control ECU connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LH Tester Connection
Condition
Specified Condition
E41-3 (MOL+) - E41-4 (MOL-)
Always
Below 100 Ω
for RH Tester Connection
Condition
Specified Condition
E41-1 (MOR-) - E41-2 (MOR+)
Always
Below 100 Ω
Result Result
Proceed to
OK
(for LHD)
A
OK
(for RHD)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. CHECK HARNESS AND CONNECTOR (FRONT SEAT OUTER BELT - SEAT BELT CONTROL ECU) |
Disconnect the E41 seat belt control ECU connector.

Disconnect the K11*1 or L5*2 front seat outer belt connector.
- HINT:
- *1: for LH
- *2: for RH
- *1: for LH
Using a service wire, connect K11-1*1 and K11-2*1 or L5-1*2 and L5-2*2 of the connector on the front seat outer belt assembly.
- NOTICE:
- Do not forcibly insert the service wire into the terminals of the connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LH Tester Connection
Condition
Specified Condition
E41-3 (MOL+) - E41-4 (MOL-)
Always
Below 1 Ω
for RH Tester Connection
Condition
Specified Condition
E41-1 (MOR-) - E41-2 (MOR+)
Always
Below 1 Ω
Result Result
Proceed to
OK
(for DTC B2002)
A
OK
(for DTC B2007)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||