INSPECTION
Inspection · Vehicles built from Jan 2012
| INSPECT GENERATOR ROTOR ASSEMBLY |
Check the resistance.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
for 130 A Type Tester Connection
Condition
Specified Condition
Slip ring - Slip ring
20°C (68°F)
2.3 to 2.7 Ω
for 150 A Type Tester Connection
Condition
Specified Condition
Slip ring - Slip ring
20°C (68°F)
1.5 to 1.9 Ω
If the result is not as specified, replace the generator rotor assembly.Text in Illustration *1
Slip Ring
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Slip ring - Rotor core
Always
10 kΩ or higher
If the result is not as specified, replace the generator rotor assembly.Text in Illustration *1
Slip Ring
*2
Rotor Core
Using a vernier caliper, measure the slip ring diameter.

- Standard diameter:
- 14.2 to 14.8 mm (0.559 to 0.583 in.)
- Minimum diameter:
- 14.0 mm (0.551 in.)
If the diameter is less than the minimum, replace the generator rotor assembly.Text in Illustration *1
Diameter
Check that the generator rotor bearing is not rough or worn.

If necessary, replace the generator rotor assembly.
| INSPECT GENERATOR BRUSH HOLDER ASSEMBLY |
Using a vernier caliper, measure the brush length.

- Standard exposed length:
- 9.5 to 11.5 mm (0.374 to 0.453 in.)
- Minimum exposed length:
- 4.5 mm (0.177 in.)
If the brush length is less than the minimum, replace the generator brush holder assembly.Text in Illustration *1
Length