ECM Power Source Circuit
Circuit diagnosis · Vehicles built from Sep 2011
DESCRIPTION
When the ignition switch is turned to ON, the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil, closing the contacts of the integration relay (EFI MAIN relay) and supplying power to terminal +B of the ECM.WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. INSPECT INTEGRATION NO.1 RELAY (INTEGRATION RELAY - BODY GROUND) |
![]() ![]() |
Remove the integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
1C-1 - Body ground
Always
11 to 14 V
Measure the voltage according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1B-3 - Body ground
Always
Below 1 Ω
1B-7 - Body ground
Always
Below 1 Ω
Reinstall the integration relay.
|
|
||||
| OK | |
| 2. INSPECT INTEGRATION NO.1 RELAY (EFI RELAY AND IG2 RELAY) |
![]() ![]() |
Remove the integration relay from the engine room relay block.
Inspect the EFI MAIN fuse and the IG2 MAIN fuse.
Remove the EFI MAIN fuse and IG2 MAIN fuse from the integration relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
EFI MAIN fuse
Always
Below 1 Ω
IG2 MAIN fuse
Always
Below 1 Ω
Inspect the EFI relay and the IG2 relay.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1C-1 - 1B-4
Battery voltage not applied to terminals 1B-2 and 1B-3
10 kΩ or higher
Battery voltage applied to terminals 1B-2 and 1B-3
Below 1 Ω
1C-1 - 1B-8
Battery voltage not applied to terminals 1B-7 and 1B-6
10 kΩ or higher
Battery voltage applied to terminals 1B-7 and 1B-6
Below 1 Ω
|
|
||||
| OK | |
| 3. INSPECT ECM (IGSW VOLTAGE) |
![]() ![]() |
Disconnect the ECM connectors.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LHD Tester Connection
Switch Condition
Specified Condition
A38-28 (IGSW) - C45-81 (E1)
Ignition switch ON
11 to 14 V
for RHD Tester Connection
Switch Condition
Specified Condition
A52-28 (IGSW) - C46-81 (E1)
Ignition switch ON
11 to 14 V
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM) |
![]() ![]() |
Check the harness and the connectors between the integration relay and the ECM.
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
for LHD Tester Connection
Condition
Specified Condition
A38-44 (MREL) - 1B-2
Always
Below 1 Ω
A38-2 (+B) - 1B-4
Always
Below 1 Ω
for RHD Tester Connection
Condition
Specified Condition
A52-44 (MREL) - 1B-2
Always
Below 1 Ω
A52-2 (+B) - 1B-4
Always
Below 1 Ω
- Standard Resistance (Check for Short):
for LHD Tester Connection
Condition
Specified Condition
A38-44 (MREL) or 1B-2 - Body ground
Always
10 kΩ or higher
A38-2 (+B) or 1B-4 - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
A52-44 (MREL) or 1B-2 - Body ground
Always
10 kΩ or higher
A52-2 (+B) or 1B-4 - Body ground
Always
10 kΩ or higher
Reconnect the ECM connector.
Reinstall the integration relay.
|
|
||||
| OK | ||
| ||
| 5. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM) |
![]() ![]() |
Check the harness and the connectors between the integration relay and the ECM.
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
for LHD Tester Connection
Condition
Specified Condition
A38-28 (IGSW) - 1B-8
Always
Below 1 Ω
for RHD Tester Connection
Condition
Specified Condition
A52-28 (IGSW) - 1B-8
Always
Below 1 Ω
- Standard Resistance (Check for Short):
for LHD Tester Connection
Condition
Specified Condition
A38-28 (IGSW) or 1B-8 - Body ground
Always
10 kΩ or higher
for RHD Tester Connection
Condition
Specified Condition
A52-28 (IGSW) or 1B-8 - Body ground
Always
10 kΩ or higher
Reconnect the ECM connector.
Reinstall the integration relay.
| Result |
Proceed to |
| OK (w/ Entry and Start System) |
A |
| OK (w/o Entry and Start System) |
B |
| NG |
C |
|
|
||||
|
|
||||
| A | |
| 6. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - INTEGRATION RELAY) |
![]() ![]() |
Remove the integration relay from the engine room relay block.
Disconnect the IG2D main body ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
E2-11 (IG2D) - 1B-6
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
E2-11 (IG2D) or 1B-6 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 7. CHECK HARNESS AND CONNECTOR (IGNITION OR STARTER SWITCH ASSEMBLY - INTEGRATION RELAY) |
Remove the integration relay from the engine room relay block.
Disconnect the Ignition or Starter Switch Assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
E93-6 (IG2) - 1B-6
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
E93-6 (IG2) or 1B-6 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 8. INSPECT IGNITION OR STARTER SWITCH ASSEMBLY |
Inspect the Ignition or Starter Switch Assembly (Click here).
|
|
||||
| OK | ||
| ||