Crawl Indicator Light Remains ON
Circuit diagnosis · Vehicles built from Jan 2012
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
When CRAWL starts after operating the CRAWL switch, the CRAWL indicator light turns on. While CRAWL is in the process of stopping, the CRAWL indicator light begins blinking. When CRAWL totally stops, the CRAWL indicator light turns off.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- After replacing the master cylinder solenoid, perform zero point calibration and store the system information (Click here).
| 1. CHECK CAN COMMUNICATION LINE |
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and the GTS on.
Select "CAN Bus Check" from the System Selection Menu screen, and follow the prompts on the screen to inspect the CAN Bus.
- OK:
- "CAN Bus Check" indicates no malfunctions in CAN communication.
Result Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
|
|
||||
|
|
||||
| A | |
| 2. CHECK DTC (CAN COMMUNICATION SYSTEM) |
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and the GTS on.
Check for DTCs (for LHD: Click here, for RHD: Click here).
Result Result
Proceed to
CAN system DTC is not output
A
CAN system DTC is output (for LHD)
B
CAN system DTC is output (for RHD)
C
|
|
||||
|
|
||||
| A | |
| 3. PERFORM ACTIVE TEST USING GTS (CRAWL CONTROL LIGHT) |
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Chassis / ABS/VSC/TRC / Active Test.
ABS/VSC/TRC Tester Display
Test Part
Control Range
Diagnostic Note
Crawl Control Light
CRAWL indicator light
Indicator light ON/OFF
Observe the combination meter.
When performing the Crawl Control Light Active Test, check Crawl Control Light in the Data List.
ABS/VSC/TRC Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Crawl Control Light
CRAWL indicator light/ ON or OFF
ON: Indicator light on
OFF: Indicator light off
-
Result Result
Proceed to
Data List Display
Data List Display when Performing Active Test ON/OFF Operation
ON
Changes between ON and OFF
A
Does not change between ON and OFF (for LHD)
B
Does not change between ON and OFF (for RHD)
C
OFF
Changes between ON and OFF
A
Does not change between ON and OFF (for LHD)
B
Does not change between ON and OFF (for RHD)
C
|
|
||||
|
|
||||
| A | ||
| ||