2011-2013 Land Cruiser · Service Manual Power Source / Network

INSPECTION

Inspection · Vehicles built from Jan 2012

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012


INSPECT GENERATOR PULLEY WITH CLUTCH

  1. A267550E01
    Using SST, hold the center of the generator pulley with clutch and check that the outer ring turns counterclockwise and does not turn clockwise.
    SST
    09820-63021  
    Text in Illustration 
    *a
    Hold
    V100135
    Free
    V100136
    Lock
    If the result is not as specified, replace the generator pulley with clutch.


INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

  1. A128079E06
    Using a vernier caliper, measure the brush length.

    Standard exposed length:
    9.5 to 11.5 mm (0.374 to 0.453 in.)

    Minimum exposed length:
    4.5 mm (0.177 in.)

    Text in Illustration 
    *1
    Length
    If the brush length is less than the minimum, replace the generator brush holder assembly.


INSPECT GENERATOR ROTOR ASSEMBLY

  1. A079306E02
    Check that the generator rotor bearing is not rough or worn.
    If necessary, replace the generator rotor assembly.

  1. Check the resistance.

    1. B012264E24
      Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Slip ring
      20°C (68°F)
      3.4 to 3.8 Ω

      Text in Illustration 
      *1
      Slip Ring
      If the result is not as specified, replace the generator rotor assembly.

    2. B012265E19
      Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Rotor core
      Always
      10 MΩ or higher

      Text in Illustration 
      *1
      Slip Ring
      *2
      Rotor Core
      If the result is not as specified, replace the generator rotor assembly.

  1. A124106E04
    Using a vernier caliper, measure the slip ring diameter.

    Standard diameter:
    14.2 to 14.8 mm (0.559 to 0.583 in.)

    Minimum diameter:
    14.0 mm (0.551 in.)

    Text in Illustration 
    *1
    Diameter
    If the diameter is less than the minimum, replace the generator rotor assembly.