INSPECTION
Inspection · Vehicles built Sep 2011 – Dec 2011
- NOTICE:
- The following tests must be done within 3 to 5 seconds to prevent the coil from burning out.
| INSPECT STARTER ASSEMBLY |
Perform pull-in test.

Remove the nut, then disconnect the lead wire from terminal C.
Connect the battery to the starter as shown in the illustration. Check that the clutch pinion gear moves outward.
If the clutch pinion gear does not move, replace the magnet starter switch assembly.
Perform holding test.

When the battery is connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.
If the clutch pinion gear returns inward, replace the magnet starter switch assembly.
Inspect clutch pinion gear return.

Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.
If the clutch pinion gear does not return inward, replace the magnet starter switch assembly.
Perform the operation test without load.

Connect the lead wire to terminal C with the nut.
- Torque:
- 5.9 N*m{ 60 kgf*cm , 52 in.*lbf }
Grip the starter in a vise.
Connect the battery and an ammeter to the starter as shown.
Check that the starter rotates smoothly and steadily with the clutch pinion gear extended.
Check that the ammeter reads the specified current.
- Standard current:
- 100 A or less at 11.5 V
| INSPECT STARTER ARMATURE ASSEMBLY |
Inspect the commutator for an open circuit.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Commutator
Always
Below 1 Ω
Inspect the commutator for a short circuit.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Commutator - Armature
Always
10 kΩ or higher
Check the commutator surface for dirt and burns.
If the surface is dirty or burnt, correct it with sandpaper (#400) or a lathe.
Inspect the commutator circle runout.

Place the commutator on V-blocks.
Using a dial indicator, measure the circle runout.
- Maximum circle runout:
- 0.05 mm (0.00197 in.)
Using a vernier caliper, measure the commutator diameter.

- Standard diameter:
- 35.0 mm (1.38 in.)
- Minimum diameter:
- 34.0 mm (1.34 in.)
Measure the undercut depth of the commutator.

- Standard undercut depth:
- 0.7 mm (0.0276 in.)
- Minimum undercut depth:
- 0.2 mm (0.00787 in.)
Inspect the bearings.
Check that the bearing rotates smoothly.
| INSPECT BRUSH |
Using a vernier caliper, measure the brush length.

- Standard brush length:
- 15.0 mm (0.591 in.)
- Minimum brush length:
- 9.0 mm (0.354 in.)
| INSPECT STARTER BRUSH HOLDER ASSEMBLY |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
Positive brush holder - Negative brush holder
Always
10 kΩ or higher
Inspect the load of the brush spring.

Take the pull scale reading immediately after the brush spring separates from the brush.
- Standard spring installed load:
- 21.5 to 27.5 N (2.2 to 2.8 kgf, 4.8 to 6.2 lbf)
- Minimum spring installed load:
- 12.7 N (1.3 kgf, 2.9 lbf)
| INSPECT STARTER YOKE ASSEMBLY |
Inspect for an open circuit.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Terminal C wire - Brush
Always
Below 1 Ω
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester connection
Condition
Specified Condition
Shunt coil terminal (A) - Shunt coil terminal (B)
20°C (68°F)
1.5 to 1.9 Ω
| INSPECT STARTER CLUTCH SUB-ASSEMBLY |
Check that the starter clutch cannot be rotated counterclockwise, and can be rotated clockwise.

If the starter clutch is not as specified, replace the starter clutch sub-assembly.
| INSPECT MAGNET STARTER SWITCH ASSEMBLY |
Inspect the pull-in coil.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Terminals 50 - Terminal C
Always
Below 1 Ω
Inspect the holding coil.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
Terminal 50 - Switch body
Always
Below 2 Ω
