B1411/11 Room Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The front room temperature sensor for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner "auto" mode. The resistance of the room temperature sensor changes in accordance with the front room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the front room temperature sensor and reads voltage changes as the resistance of the front room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier assembly.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1411/11 |
An open or short in the front room temperature sensor circuit. |
|
WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (FRONT ROOM TEMPERATURE SENSOR) |
Use the Data List to check if the front room temperature sensor is functioning properly.
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Room Temperature Sensor
Front room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature for front seat displayed
Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
- OK:
- The display is as specified in the normal condition.
|
|
||||
| OK | ||
| ||
| 2. INSPECT ROOM TEMPERATURE SENSOR |
![]() ![]() |
Remove the front room temperature sensor (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (+) - 2 (-)
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (FRONT ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
w/ Rear Heater

Disconnect the E32 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E32-1 (+) - E35-9 (TR)
Always
Below 1 Ω
E32-2 (-) - E35-32 (SG-1)
E35-9 (TR) - Body ground
Always
10 kΩ or higher
E35-32 (SG-1) - Body ground
w/o Rear Heater

Disconnect the E32 sensor connector.
Disconnect the E81 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E32-1 (+) - E81-29 (TR)
Always
Below 1 Ω
E32-2 (-) - E81-34 (SG-1)
E81-29 (TR) - Body ground
Always
10 kΩ or higher
E81-34 (SG-1) - Body ground
|
|
||||
| OK | ||
| ||