B1412/12 Ambient Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Jan 2012
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The ambient temperature sensor is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner "auto" mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1412/12 |
An open or short in the ambient temperature sensor circuit. |
|
WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR) |
Use the Data List to check if the ambient temperature sensor is functioning properly.
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sensor
Ambient temperature sensor /
Min: -23.3°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed
Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
- OK:
- The display is as specified in the normal condition.
|
|
||||
| OK | ||
| ||
| 2. INSPECT AMBIENT TEMPERATURE SENSOR |
![]() ![]() |
Remove the ambient temperature sensor (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (+) - 2 (-)
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() ![]() |
w/ Rear Heater
Disconnect the A14 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A14 (+) -1 - E35-10 (TAM)
Always
Below 1 Ω
A14-2 (-) - E35-16 (SG-2)
E35-10 (TAM) - Body ground
Always
10 kΩ or higher
E35-16 (SG-2) - Body ground
w/o Rear Heater

Disconnect the A14 sensor connector.
Disconnect the E81 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A14-1 (+) - E81-5 (TAM)
Always
Below 1 Ω
A14-2 (-) - E81-13 (SG-2)
E81-5 (TAM) - Body ground
Always
10 kΩ or higher
E81-13 (SG-2) - Body ground
|
|
||||
| OK | ||
| ||