2011-2013 Land Cruiser · Service Manual Vehicle Interior

B1412/12 Ambient Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

The ambient temperature sensor is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner "auto" mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
DTC Code
DTC Detection Condition
Trouble Area
B1412/12
An open or short in the ambient temperature sensor circuit.
  1. Ambient temperature sensor
  2. Harness or connector between ambient temperature sensor and air conditioning amplifier assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM

E156584E38
E156584E39

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR)
  1. Use the Data List to check if the ambient temperature sensor is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Ambient temperature sensor /
    Min: -23.3°C (-9.94°F)
    Max: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    Open in the circuit: -23.3°C (-9.94°F).
    Short in the circuit: 65.95°C (150.71°F).

    OK:
    The display is as specified in the normal condition.



NG
Go to step 2
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

2. INSPECT AMBIENT TEMPERATURE SENSOR
E106870E18
  1. Remove the ambient temperature sensor (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (+) - 2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE AMBIENT TEMPERATURE SENSOR (Click here)
OK


3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E156621E04
  1. w/ Rear Heater

    1. Disconnect the A14 sensor connector.

    2. Disconnect the E35 amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      A14 (+) -1 - E35-10 (TAM)
      Always
      Below 1 Ω
      A14-2 (-) - E35-16 (SG-2)
      E35-10 (TAM) - Body ground
      Always
      10 kΩ or higher
      E35-16 (SG-2) - Body ground

  1. E160289E02
    w/o Rear Heater
    1. Disconnect the A14 sensor connector.

    2. Disconnect the E81 amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      A14-1 (+) - E81-5 (TAM)
      Always
      Below 1 Ω
      A14-2 (-) - E81-13 (SG-2)
      E81-5 (TAM) - Body ground
      Always
      10 kΩ or higher
      E81-13 (SG-2) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)


← B1411/11 Room Temperature Sensor Circuit (from Jan 2012)B1412/12 Ambient Temperature Sensor Circuit (from Jan 2012) →