B1500 Fuel Sender Open Detected
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
This DTC is output when the combination meter detects a fuel sender gauge malfunction via the CAN.| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1500 |
When the combination meter detects a fuel sender gauge malfunction. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (FUEL SENDER GAUGE) |
Operate the intelligent tester according to the display and select the Data List (Click here).
Combination Meter Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Fuel Input
Fuel sender gauge (main) input signal/Min.: 0, Max.: 127.5
Fuel sender input value
Unit: L
- OK:
- Fuel value displayed on the intelligent tester is almost the same as needle indication.
Result Result
Proceed to
NG
A
OK (w/ Multi-information Display)
B
OK (w/o Multi-information Display)
C
|
|
||||
|
|
||||
| A | |
| 2. CHECK HARNESS AND CONNECTOR (COMBINATION METER - PUMP AND GAUGE AND BODY GROUND) |


Disconnect the E7 and E8 combination meter assembly connectors.
Disconnect the N1 fuel suction with pump and gauge tube assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E8-9 (L) - N1-2 (FS)
Always
Below 1 Ω
E8-21 (E) - N1-3 (FE)
Always
Below 1 Ω
E7-15 (ET) - Body ground
Always
Below 1 Ω
E8-9 (L) or N1-2 (FS) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 3. INSPECT FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY |
![]() ![]() |
Remove the fuel sender gauge assembly.
- HINT:
- for 1GR-FE (Click here)
- for 2UZ-FE (Click here)
- for 3UR-FE (Click here)
- for 1VD-FTV (Click here)
- for 1GR-FE (Click here)
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A-2 (FS) - B-2 (FS)
Always
Below 1 Ω
A-3 (FE) - B-1 (FE)
Always
Below 1 Ω
Text in Illustration *1
Component without harness connected
(Fuel Suction with Pump and Gauge Tube Assembly)
*2
Connector A
*3
Connector B
Result Result
Proceed to
OK
A
NG (for 1GR-FE)
B
NG (for 2UZ-FE)
C
NG (for 3UR-FE)
D
NG (for 1VD-FTV)
E
|
|
||||
|
|
||||
|
|
||||
|
|
||||
| A | |
| 4. INSPECT FUEL SENDER GAUGE ASSEMBLY |
![]() ![]() |
Remove the fuel sender gauge assembly.
- HINT:
- for 1GR-FE (Click here)
- for 2UZ-FE (Click here)
- for 3UR-FE (Click here)
- for 1VD-FTV (Click here)
- for 1GR-FE (Click here)
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
2 (FS) - 1 (FE)
Float level is F (upper)
13.5 to 16.5 Ω
Float level is E (lower)
405.5 to 414.5 Ω
Text in Illustration *1
Component without harness connected
(Fuel Sender Gauge Assembly)
Result Result
Proceed to
OK
A
NG (for 1GR-FE)
B
NG (for 2UZ-FE)
C
NG (for 3UR-FE)
D
NG (for 1VD-FTV)
E
|
|
||||
|
|
||||
|
|
||||
|
|
||||
| A | |
| 5. CHECK COMBINATION METER TYPE |
Check the combination meter type
Result Result
Proceed to
w/ Multi-information Display
A
w/o Multi-information Display
B
|
|
||||
| A | ||
| ||