INSPECTION
Inspection · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
| INSPECT NO. 2 ULTRASONIC SENSOR |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (BI) - 3 (SI)
Always
10 kΩ or higher
| INSTALL NO. 3 ULTRASONIC SENSOR |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (BI) - 3 (SI)
Always
10 kΩ or higher