INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT FRONT SHOCK ABSORBER CONTROL VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
for RH Tester Connection
Condition
Specified Condition
1 (FAR+) - 2 (E FR)
Always
12.0 to 13.6 Ω
3 (FBR-) - 2 (E FR)
4 (FAR-) - 2 (E FR)
5 (FBR+) - 2 (E FR)
for LH Tester Connection
Condition
Specified Condition
1 (FAL+) - 2 (E FL)
Always
12.0 to 13.6 Ω
3 (FBL-) - 2 (E FL)
4 (FAL-) - 2 (E FL)
5 (FBL+) - 2 (E FL)
- If the result is not as specified, replace the shock absorber control valve.
| INSPECT FRONT SUSPENSION CONTROL VALVE ASSEMBLY |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
for RH Tester Connection
Condition
Specified Condition
1 (CRFR) - 2 (SLB)
20°C (68°F)
4.58 to 5.02 Ω
for LH Tester Connection
Condition
Specified Condition
1 (CRFL) - 2 (SLB)
20°C (68°F)
4.58 to 5.02 Ω
- If the result is not as specified, replace the shock absorber control valve.