TERMINALS OF ECU
System information · Vehicles built from Jan 2012
| CHECK NO. 2 MAIN BODY ECU |


Disconnect the L50 and L51 No. 2 main body ECU connectors.
Measure the voltage and resistance according to the value(s) in the table below.
If the result is not as specified, there may be a malfunction on the wire harness side.Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
L50-14 (BECU) - Body ground
R - Body ground
BECU power supply
Always
11 to 14 V
L50-13 (SIG) - Body ground
G - Body ground
SIG power supply
Engine switch on (IG)
11 to 14 V
L50-13 (SIG) - Body ground
G - Body ground
SIG power supply
Engine switch off
Below 1 V
L51-5 (B) - Body ground
B - Body ground
Lower tail gate lock motor RH power supply
Always
11 to 14 V
L51-6 (B) - Body ground
W - Body ground
Lower tail gate lock motor LH power supply
Always
11 to 14 V
L50-7 (GND) - Body ground
W-B - Body ground
Body ground
Always
Below 1 Ω
L51-7 (GND) - Body ground
W-B - Body ground
Body ground
Always
Below 1 Ω
L50-19 (BDSU) - Body ground
V - Body ground
Back door remote control signal circuit
Back door remote control pulled (on)
Below 1 Ω
L50-19 (BDSU) - Body ground
V - Body ground
Back door remote control signal circuit
Back door remote control free (off)
10 kΩ or higher
Reconnect the L50 and L51 No. 2 main body ECU connectors.
Measure the voltage according to the value(s) in the table below.
Terminal No. (Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
L51-3 (DC+) - L51-7 (GND)
R - W-B
Lower tail gate lock motor LH circuit
Lower tail gate lock motor LH operating (close)
11 to 14 V
L51-3 (DC+) - L51-7 (GND)
R - W-B
Lower tail gate lock motor LH circuit
Lower tail gate lock motor LH stopped
Below 1 V
L51-8 (DC-) - L51-7 (GND)
B - W-B
Lower tail gate lock motor LH circuit
Lower tail gate lock motor LH operating (open)
11 to 14 V
L51-8 (DC-) - L51-7 (GND)
B - W-B
Lower tail gate lock motor LH circuit
Lower tail gate lock motor LH stopped
Below 1 V
L51-2 (DC+) - L51-7 (GND)
G - W-B
Lower tail gate lock motor RH circuit
Lower tail gate lock motor RH operating (close)
11 to 14 V
L51-2 (DC+) - L51-7 (GND)
G - W-B
Lower tail gate lock motor RH circuit
Lower tail gate lock motor RH stopped
Below 1 V
L51-1 (DC-) - L51-7 (GND)
W - W-B
Lower tail gate lock motor RH circuit
Lower tail gate lock motor RH operating (open)
11 to 14 V
L51-1 (DC-) - L51-7 (GND)
W - W-B
Lower tail gate lock motor RH circuit
Lower tail gate lock motor RH stopped
Below 1 V
L51-9 (HAF) - L51-7 (GND)
GR - W-B
Half-latch switch LH signal circuit
Lower tail gate open
Below 1 V
L51-9 (HAF) - L51-7 (GND)
GR - W-B
Half-latch switch LH signal circuit
Lower tail gate closed
Pulse generation
(See waveform 1)
L50-8 (HAF) - L51-7 (GND)
B - W-B
Half-latch switch RH signal circuit
Lower tail gate open
Below 1 V
L50-8 (HAF) - L51-7 (GND)
B - W-B
Half-latch switch RH signal circuit
Lower tail gate closed
Pulse generation
(See waveform 1)
L51-4 (FUL) - L51-7 (GND)
G - W-B
Lower tail gate courtesy switch LH signal circuit
Lower tail gate open
Below 1 V
L51-4 (FUL) - L51-7 (GND)
G - W-B
Lower tail gate courtesy switch LH signal circuit
Lower tail gate closed
Pulse generation
(See waveform 1)
L50-22 (FUL) - L51-7 (GND)
Y - W-B
Lower tail gate courtesy switch RH signal circuit
Lower tail gate open
Below 1 V
L50-22 (FUL) - L51-7 (GND)
Y - W-B
Lower tail gate courtesy switch RH signal circuit
Lower tail gate closed
Pulse generation
(See waveform 1)
L51-10 (LMT) - L51-7 (GND)
Y - W-B
Close position switch LH signal circuit
Lower tail gate closed
Below 1 V
L51-10 (LMT) - L51-7 (GND)
Y - W-B
Close position switch LH signal circuit
Lower tail gate open
Pulse generation
(See waveform 2)
L50-17 (LMT) - L51-7 (GND)
L - W-B
Close position switch RH signal circuit
Lower tail gate closed
Below 1 V
L50-17 (LMT) - L51-7 (GND)
L - W-B
Close position switch RH signal circuit
Lower tail gate open
Pulse generation
(See waveform 2)
L50-15 (POL) - L51-7 (GND)
L - W-B
Pawl switch LH signal circuit
Lower tail gate lock motor LH is operating
Below 1 V
L50-15 (POL) - L51-7 (GND)
L - W-B
Pawl switch LH signal circuit
Lower tail gate open
Pulse generation
(See waveform 2)
L50-16 (POL) - L51-7 (GND)
R - W-B
Pawl switch RH signal circuit
Lower tail gate lock motor RH is operating
Below 1 V
L50-16 (POL) - L51-7 (GND)
R - W-B
Pawl switch RH signal circuit
Lower tail gate open
Pulse generation
(See waveform 2)
L50-19 (BDSU) - L51-7 (GND)
V - W-B
Back door remote control signal circuit
Back door remote control pulled (on)
Below 1 V
L50-19 (BDSU) - L51-7 (GND)
V - W-B
Back door remote control signal circuit
Back door remote control free (off)
Pulse generation
(See waveform 3)
Using an oscilloscope, check waveform 1.

Waveform 1 (Reference) Item
Content
Terminal (Symbol)
- L51-9 (HAF) - L51-7 (GND)
- L50-8 (HAF) - L51-7 (GND)
- L51-4 (FUL) - L51-7 (GND)
- L50-22 (FUL) - L51-7 (GND)
Tool Setting
5 V/DIV., 5 ms/DIV
Condition
Lower tail gate closed
- L51-9 (HAF) - L51-7 (GND)
Using an oscilloscope, check waveform 2.

Waveform 2 (Reference) Item
Content
Terminal (Symbol)
- L51-10 (LMT) - L51-7 (GND)
- L50-17 (LMT) - L51-7 (GND)
- L51-15 (POS) - L51-7 (GND)
- L50-16 (POS) - L51-7 (GND)
Tool Setting
5 V/DIV., 5 ms/DIV
Condition
Lower tail gate open
- L51-10 (LMT) - L51-7 (GND)
Using an oscilloscope, check waveform 3.

Waveform 3 (Reference) Item
Content
Terminal (Symbol)
L50-19 (BDSU) - L51-7 (GND)
Tool Setting
5 V/DIV., 5 ms/DIV
Condition
Back door remote control free (off)