Home › General › BODY ELECTRICAL › AIR CONDITIONING
NM2660E _V1 General _054361 BODY ELECTRICAL _0269833 AIR CONDITIONING UN GENERAL/CONTROL/DETAILS F

BODY ELECTRICAL  AIR CONDITIONING  GENERAL/CONTROL/DETAILS  MODE POSITION AND DAMPER OPERATION  


MODE POSITION AND DAMPER OPERATION


Front Air Conditioning (Models with Multi-zone Automatic Climate Control)
Y196841C01
0.5,3.26 0.844,2.833 true 1.313,3.438 1.865,2.896 true 2.125,3.51 2.729,2.865 true 2.469,3.646 2.958,2.521 true 2.083,0.479 2.396,0.635 0.313,0.156 10 false *1 3.26,0.792 3.573,0.948 0.313,0.156 10 false *2 0.302,3.156 0.615,3.313 0.313,0.156 10 false *3 1.115,3.333 1.427,3.49 0.313,0.156 10 false *4 1.938,3.385 2.25,3.542 0.313,0.156 10 false *5 2.333,3.646 2.646,3.802 0.313,0.156 10 false *6 2.969,4.021 3.281,4.177 0.313,0.156 10 false *7 3.563,4.031 3.875,4.188 0.313,0.156 10 false *8 4.292,4.031 4.604,4.188 0.313,0.156 10 false *9 5.063,4.021 5.531,4.177 0.469,0.156 10 false *10 3.604,2.396 4.073,2.552 0.469,0.156 10 false *11 0.229,1.833 0.542,1.99 0.313,0.156 10 false *a 1.031,2.042 1.344,2.198 0.313,0.156 10 false *b 4.854,2.406 5.323,2.563 0.469,0.156 10 false *11 1.031,0.802 1.344,0.958 0.313,0.156 10 false *2 6.323,4.031 6.635,4.188 0.313,0.156 10 false *8 6.844,4.031 7.156,4.188 0.313,0.156 10 false *7
*1 Center Defroster *2 Side Defroster
*3 Blower Motor *4 Evaporator
*5 Heater Radiator Unit *6 PTC Heater Assembly
*7 Side Register *8 Rear Foot Well Register Duct
*9 Front Center Register *10 Rear Center Register
*11 Front Foot Well Register Duct - -
*a Fresh Air *b Recirc Air


Function of Main Damper
Control Damper Operation Position Damper Position Operation
Air Inlet Control Damper FRESH A Brings in fresh air.
RECIRC B Recirculates internal air.
Air Mix Control Damper MAX COLD to MAX HOT Temp. Setting K-L-M Varies the mixture ratio of the cold air and the hot air in order to regulate the temperature continuously from HOT to COLD.
Cool Air Bypass Damper MAX COLD to MAX HOT Temp. Setting H-I-J Cool air blows out from the front center register and side registers, in order to adjust the temperature around the heads of the occupants during cooling or warming.
Mode Control Damper
Y130488

DEF C Defrosts the windshield through the center defroster, and side defroster.
Y130487

FOOT/DEF D Defrosts the windshield through the center defroster, side defroster, while air is also blown out from the front and rear footwell register ducts. In addition, air blows out slightly from front and rear center registers and side register.
Y130486

FOOT E Air blows out of the front and rear footwell register duct, front and rear center register, and side register. In addition, air blows out slightly from the center defroster, side defroster and side register
Y130485

BI-LEVEL F Air blows out of the front and rear center registers, side register, and front and rear footwell register ducts.
Y130484

FACE G Air blows out of the front and rear center registers, and side register.

Front Air Conditioning Unit (Models with Left/right Independent Temperature Contol)
Y202873C01
0.344,2.99 0.698,2.781 true 1.656,3.313 1.865,2.969 true 2.469,3.281 2.698,2.927 true 2.604,3.385 2.948,2.594 true 2.094,0.573 2.406,0.729 0.313,0.156 10 false *1 3.229,0.865 3.542,1.021 0.313,0.156 10 false *2 0.229,3.021 0.542,3.177 0.313,0.156 10 false *3 1.521,3.333 1.833,3.49 0.313,0.156 10 false *4 2.302,3.25 2.615,3.406 0.313,0.156 10 false *5 2.51,3.458 2.823,3.615 0.313,0.156 10 false *6 2.979,4.042 3.292,4.198 0.313,0.156 10 false *7 3.563,4.031 3.875,4.188 0.313,0.156 10 false *8 4.271,4.042 4.583,4.198 0.313,0.156 10 false *9 5.042,4.073 5.51,4.229 0.469,0.156 10 false *10 4.917,2.479 5.385,2.635 0.469,0.156 10 false *11 0.219,1.854 0.531,2.01 0.313,0.156 10 false *a 1.135,2.073 1.448,2.229 0.313,0.156 10 false *b 1.052,0.885 1.365,1.042 0.313,0.156 10 false *2 6.281,4.042 6.594,4.198 0.313,0.156 10 false *8 6.781,4.063 7.094,4.219 0.313,0.156 10 false *7 3.615,2.49 4.083,2.646 0.469,0.156 10 false *11
*1 Center Defroster *2 Side Defroster
*3 Blower Motor *4 Evaporator
*5 Heater Radiator Unit *6 PTC Heater Assembly
*7 Side Register *8 Rear Foot Well Register Duct
*9 Front Center Register *10 Rear Center Register
*11 Front Foot Well Register Duct - -
*a Fresh Air *b Recirc Air


Function of Main Damper
Control Damper Operation Position Damper Position Operation
Air Inlet Control Damper FRESH A Brings in fresh air.
RECIRC B Recirculates internal air.
Air Mix Control Damper MAX COLD to MAX HOT Temp. Setting K-L-M Varies the mixture ratio of the cold air and the hot air in order to regulate the temperature continuously from HOT to COLD.
Cool Air Bypass Damper MAX COLD to MAX HOT Temp. Setting H-I-J Cool air blows out from the front center register and side registers, in order to adjust the temperature around the heads of the occupants during cooling or warming.
Mode Control Damper
Y130488

DEF C Defrosts the windshield through the center defroster, and side defroster.
Y130487

FOOT/DEF D Defrosts the windshield through the center defroster, side defroster, while air is also blown out from the front and rear footwell register ducts. In addition, air blows out slightly from front and rear center registers and side register.
Y130486

FOOT E Air blows out of the front and rear footwell register duct, front and rear center register, and side register. In addition, air blows out slightly from the center defroster, side defroster and side register
Y130485

BI-LEVEL F Air blows out of the front and rear center registers, side register, and front and rear footwell register ducts.
Y130484

FACE G Air blows out of the front and rear center registers, and side register.

Rear Air Conditioning
Y196842C01
1.396,2.938 2.198,2.333 true 2.771,0.552 3.229,1.302 true 2.615,0.365 2.927,0.521 0.313,0.156 10 false *1 1.219,2.823 1.531,2.979 0.313,0.156 10 false *2 5.135,0.948 5.448,1.104 0.313,0.156 10 false *3 3.833,0.677 4.146,0.833 0.313,0.156 10 false *4
*1 Heater Radiator Unit *2 Blower Motor
*3 Rear Roof Side Register *4 Rear Foot Well Register


Function of Main Damper
Control Damper Operation Position Damper Position Operation
Mode Control Damper
Y130484

FACE A Air blows out of the rear roof side register.
Y130485

BI-LEVEL B Air blows out of the rear roof side register and the rear footwell register.
Y130486

FOOT C Air blows out of the rear footwell register.
Air Mix Control Damper MAX COLD to MAX HOT Temp. Setting D-E Varies the mixture ratio of the cold air and the hot air in order to regulate the temperature continuously from HOT to COLD.