INITIALIZE FUNCTION DURING PART REPLACEMENT
The initialize function must always be performed whenever one of the conditions indicated in the table below occurs.
| Parts Name | Condition | Initialize Item |
|---|---|---|
| Television Camera Assembly | ·
Camera position has shifted. ·
Removal and reassembly ·
Replacement ·
Deformation due to the mount area having been struck. |
·
Camera position adjustment -
Vertical position -
Horizontal position -
Roll angle, pan angle, tilt angle |
| Parking Assist ECU | Replacement | ·
Neutral steering point in memory ·
Maximum side-to-side steering angle in memory ·
Camera position adjustment -
Vertical position -
Horizontal position -
Roll angle, pan angle, tilt angle |
| Steering Sensor | ·
Replacement ·
Removal and reassembly |
·
Neutral steering point in memory ·
Maximum side-to-side steering angle in memory |
The initialize function described above is performed on the diagnosis menu screen.
The method for displaying the diagnosis menu screen is the same as for the multi-display.
For details, refer to the Repair Manual.