RM2660E
_V1
General
_052771
SPECIFICATIONS
_0254948
3UR-FE COOLING
F
SPECIFICATIONS 3UR-FE COOLING SERVICE DATA
Coolant
| With rear heater
|
16.2 liters (17.1 US qts, 14.3 Imp. qts)
|
| Without rear heater
|
13.4 liters (14.2 US qts, 11.8 Imp. qts)
|
Water Inlet with Thermostat
| Standard valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Standard valve lift
|
10.0 mm (0.394 in.) or more at 95°C (203°F)
|
Radiator Cap
| Standard value (for brand-new cap)
|
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
|
| Minimum standard value (after using cap)
|
79 kPa (0.8 kgf/cm2, 11.4 psi)
|
Fin for blockage
| 300 mm (11.8 in.)
|
2942 to 4903 kPa (30.0 to 50.0 kgf/cm2, 427 to 711 psi)
|
| 500 mm (19.7 in.)
|
4903 to 7845 kPa (50.0 to 80.0 kgf/cm2, 711 to 1138 psi)
|