Hide 89465 1.INSPECT HEATED OXYGEN SENSOR

a.
A231430E01
0.17,0.407 0.394,0.570 0.224,0.162 10 *A 0.17,2.541 0.394,2.704 0.224,0.162 10 *B 0.116,0.076 0.340,0.238 0.224,0.162 10 *a 1.959,1.3 2.4,0.765 2.4,0.765 2.483,0.765 false 1.383,1.3 0.943,0.765 0.943,0.765 0.86,0.765 false 2.508,0.68 2.900,0.846 0.391,0.166 10 HT1B 0.606,0.68 0.808,0.846 0.202,0.166 10 +B 1.383,1.786 0.943,2.321 0.943,2.321 0.86,2.321 false 0.606,2.244 0.808,2.410 0.202,0.166 10 E1 1.442,3.403 1.001,2.867 1.001,2.867 0.918,2.867 false 2.567,2.783 2.989,2.948 0.422,0.166 10 HT2B 0.665,2.783 0.866,2.948 0.202,0.166 10 +B 0.665,4.259 0.866,4.424 0.202,0.166 10 E1 2.018,3.403 2.459,2.867 2.459,2.867 2.541,2.867 false 1.442,3.8 1.001,4.336 1.001,4.336 0.918,4.336 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT1B) - 4 (E1) Always 10 kΩ or higher


Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω
1 (HT2B) - 4 (E1) Always 10 kΩ or higher


Text in Illustration
*A for Bank 1
*B for Bank 2
*a Component without harness connected
(Heated Oxygen Sensor)

If the result is not as specified, replace the heated oxygen sensor.