Home › Engine / Hybrid System › 1UR-FE (ENGINE CONTROL) › SFI SYSTEM › from 2015.08
RM2660E _51 Engine / Hybrid System _052772 1UR-FE ENGINE CONTROL _0254983 SFI SYSTEM C

1UR-FE ENGINE CONTROL  SFI SYSTEM  P0112  Intake Air Temperature Circuit Low Input  P0113  Intake Air Temperature Circuit High Input  


DESCRIPTION

A385039E01
1.865,2.302 2.24,1.844 false 0.156,0.073 0.594,0.323 0.438,0.25 10 false Fig. 1 0.135,0.448 0.99,0.698 0.854,0.25 10 false Resistance 0.052,0.802 0.385,1.042 0.333,0.24 10 false (kΩ) 1.938,1.615 2.729,1.854 0.792,0.24 10 false Acceptable 3.083,4.052 3.417,4.292 0.333,0.24 10 false (°C) 3.094,4.24 3.354,4.469 0.26,0.229 10 false (°F) 1.229,4.229 2.156,4.49 0.927,0.26 10 false Temperature

The intake air temperature sensor, mounted on the mass air flow meter, monitors the intake air temperature. The intake air temperature sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the intake air temperature is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).

The intake air temperature sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.

Resistor R and the intake air temperature sensor are connected in series. When the resistance value of the intake air temperature sensor changes according to changes in the intake air temperature, the voltage at terminal THA also varies. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.

HINT:

When DTC P0112 or P0113 is stored, the ECM enters fail-safe mode. During fail-safe mode, the intake air temperature is estimated to be 20°C (68°F) by the ECM. The ECM continues operating in fail-safe mode until a pass condition is detected.



DTC No. DTC Detection Condition Trouble Area
P0112 Short in the intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic).
·

Short in intake air temperature sensor circuit

·

Intake air temperature sensor (built into mass air flow meter assembly)

·

ECM


P0113 Open in the intake air temperature sensor circuit for 0.5 seconds (1 trip detection logic).
·

Open in intake air temperature sensor circuit

·

Intake air temperature sensor (built into mass air flow meter assembly)

·

ECM



HINT:

When either of these DTCs is stored, check the intake air temperature by entering the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
140°C (284°F) or higher Short circuit


MONITOR DESCRIPTION

The ECM monitors the sensor voltage and uses this value to calculate the intake air temperature. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the intake air temperature sensor and stores a DTC.

Example:

If the sensor output voltage is higher than 4.91 V for 0.5 seconds or more, the ECM determines that there is an open in the intake air temperature sensor circuit and stores DTC P0113. Conversely, if the output voltage is below 0.18 V for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit and stores DTC P0112.

If the malfunction is not repaired successfully, a DTC is stored 0.5 seconds after the engine is next started.

CONFIRMATION DRIVING PATTERN

1.

Turn the engine switch on (IG) and wait for 5 seconds or more.


WIRING DIAGRAM

U163114E01
0.402,1.822 0.711,1.985 0.309,0.163 10 C50 0.403,1.997 2.373,2.167 1.970,0.170 10 Mass Air Flow Meter Assembly 2.07,0.616 2.399,0.754 0.330,0.139 10 THA 2.175,1.232 2.379,1.374 0.205,0.142 10 E2 2.431,0.613 2.553,0.776 0.121,0.163 10 4 2.431,1.23 2.553,1.393 0.121,0.163 10 5 5.185,0.719 5.473,0.888 0.288,0.170 10 C45 5.185,1.335 5.473,1.505 0.288,0.170 10 C45 5.175,0.549 5.503,0.702 0.328,0.152 10 73*2 5.171,1.166 5.474,1.318 0.304,0.152 10 98*2 5.521,0.615 5.851,0.757 0.330,0.142 10 THA 5.521,1.238 5.735,1.380 0.214,0.142 10 E2 5.958,2.246 6.323,2.419 0.364,0.173 10 ECM 6.246,0.249 6.513,0.412 0.267,0.163 10 5 V 4.848,0.719 5.136,0.888 0.288,0.170 10 C46 4.848,1.335 5.136,1.505 0.288,0.170 10 C46 4.838,0.549 5.166,0.702 0.328,0.152 10 73*1 4.834,1.166 5.138,1.318 0.304,0.152 10 98*1 3.332,2.041 4.096,2.209 0.765,0.167 10 *1: for RHD 3.332,2.27 4.096,2.438 0.765,0.167 10 *2: for LHD

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.READ VALUE USING GTS (INTAKE AIR)
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.


e.

Read the value displayed on the GTS.

OK:

Same as actual intake air temperature


Result
Result Proceed to
-40°C (-40°F) A
140°C (284°F) or higher B
Same as actual intake air temperature C

HINT:
·

If there is an open circuit, the GTS indicates -40°C (-40°F).


·

If there is a short circuit, the GTS indicates 140°C (284°F) or higher.





A

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

B

4.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)

C

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)
U162829E01
0.796,1.689 0.956,1.870 0.160,0.182 10 *1 2.665,1.689 2.825,1.870 0.160,0.182 10 *2 2.448,0.984 2.780,1.144 0.332,0.161 10 THA 2.445,1.173 2.652,1.320 0.207,0.147 10 E2 0.405,3.307 0.694,3.469 0.289,0.162 10 C50 1.479,0.622 1.768,0.785 0.289,0.162 10 C50 1.087,4.023 1.423,4.184 0.336,0.161 10 THA 1.752,4.026 1.972,4.187 0.221,0.161 10 E2 1.313,4.003 1.883,3.47 false 1.872,4.002 2.031,3.463 false 0.081,2.276 0.264,2.450 0.182,0.174 10 *a 1.799,1.018 1.920,1.160 0.121,0.142 10 4 1.799,1.405 1.920,1.547 0.121,0.142 10 5

a.

Disconnect the mass air flow meter connector.


b.

Connect terminals 4 (THA) and 5 (E2) of the mass air flow meter wire harness side connector.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG).


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.


g.

Read the value displayed on the GTS.

Standard value:

140°C (284°F) or higher


Text in Illustration
*1 Mass air flow meter assembly
*2 ECM
*a Front view of wire harness connector
(to Mass Air Flow Meter Assembly)



OK

CONFIRM GOOD CONNECTION TO SENSOR. IF OK, REPLACE MASS AIR FLOW METER ASSEMBLY

NG

3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
a.

Disconnect the mass air flow meter connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for RHD
Tester Connection Condition Specified Condition
C50-4 (THA) - C46-73 (THA) Always Below 1 Ω
C50-5 (E2) - C46-98 (E2) Always Below 1 Ω

for LHD
Tester Connection Condition Specified Condition
C50-4 (THA) - C45-73 (THA) Always Below 1 Ω
C50-5 (E2) - C45-98 (E2) Always Below 1 Ω




OK

CONFIRM GOOD CONNECTION TO ECM. IF OK, REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
U163265E02
1.417,0.698 1.698,0.875 0.281,0.177 10 false C50 2.635,1.698 2.813,1.854 0.177,0.156 10 false *2 0.729,1.698 0.906,1.854 0.177,0.156 10 false *1 2.458,1.49 2.677,1.646 0.219,0.156 10 false E2 2.51,1.042 2.823,1.198 0.313,0.156 10 false THA

a.

Disconnect the mass air flow meter connector.


b.

Connect the GTS to the DLC3.


c.

Turn the engine switch on (IG).


d.

Turn the GTS on.


e.

Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.


f.

Read the value displayed on the GTS.

Standard value:

-40°C (-40°F)


Text in Illustration
*1 Mass Air Flow Meter Assembly
*2 ECM



OK

NG

5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
a.

Disconnect the mass air flow meter connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for RHD
Tester Connection Condition Specified Condition
C50-4 (THA) or C46-73 (THA) - Body ground Always 10 kΩ or higher

for LHD
Tester Connection Condition Specified Condition
C50-4 (THA) or C45-73 (THA) - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR