When the ignition switch is turned to ON, the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil, closing the contacts of the integration relay (EFI MAIN relay) and supplying power to terminal +B of the ECM.
Remove the integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - Body ground | Always | 11 to 14 V |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-3 - Body ground | Always | Below 1 Ω |
| 1B-7 - Body ground | Always | Below 1 Ω |
Reinstall the integration relay.
OK
NG
Remove the integration relay from the engine room relay block.
Inspect the EFI MAIN fuse and the IG2 MAIN fuse.
Remove the EFI MAIN fuse and IG2 MAIN fuse from the integration relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EFI MAIN fuse | Always | Below 1 Ω |
| IG2 MAIN fuse | Always | Below 1 Ω |
Inspect the EFI relay and the IG2 relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - 1B-4 | Battery voltage not applied to terminals 1B-2 and 1B-3 | 10 kΩ or higher |
| Battery voltage applied to terminals 1B-2 and 1B-3 | Below 1 Ω | |
| 1C-1 - 1B-8 | Battery voltage not applied to terminals 1B-7 and 1B-6 | 10 kΩ or higher |
| Battery voltage applied to terminals 1B-7 and 1B-6 | Below 1 Ω |
OK
NG
Disconnect the ECM connectors.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-28 (IGSW) - C45-81 (E1) | Ignition switch ON | 11 to 14 V |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A52-28 (IGSW) - C46-81 (E1) | Ignition switch ON | 11 to 14 V |
OK
NG
Check the harness and the connectors between the integration relay and the ECM.
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-44 (MREL) - 1B-2 | Always | Below 1 Ω |
| A38-2 (+B) - 1B-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A52-44 (MREL) - 1B-2 | Always | Below 1 Ω |
| A52-2 (+B) - 1B-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-44 (MREL) or 1B-2 - Body ground | Always | 10 kΩ or higher |
| A38-2 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A52-44 (MREL) or 1B-2 - Body ground | Always | 10 kΩ or higher |
| A52-2 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the integration relay.
OK
NG
Check the harness and the connectors between the integration relay and the ECM.
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-28 (IGSW) - 1B-8 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A52-28 (IGSW) - 1B-8 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-28 (IGSW) or 1B-8 - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A52-28 (IGSW) or 1B-8 - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the integration relay.
| Result | Proceed to |
|---|---|
| OK (w/ Entry and Start System) | A |
| OK (w/o Entry and Start System) | B |
| NG | C |
A
B
C
Remove the integration relay from the engine room relay block.
Disconnect the IG2D main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E2-11 (IG2D) - 1B-6 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E2-11 (IG2D) or 1B-6 - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the integration relay from the engine room relay block.
Disconnect the Ignition or Starter Switch Assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E93-6 (IG2) - 1B-6 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E93-6 (IG2) or 1B-6 - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the Ignition or Starter Switch Assembly (See page Engine / Hybrid System>1VD-FTV (STARTING)>IGNITION SWITCH>INSPECTION).
OK
NG