Home › Engine / Hybrid System › 1VD-FTV (ENGINE CONTROL) › MASS AIR FLOW METER (w/o DPF)
RM2660E _51 Engine / Hybrid System _052773 1VD-FTV ENGINE CONTROL _0254985 MASS AIR FLOW METER(w/o DPF) G

1VD-FTV ENGINE CONTROL  MASS AIR FLOW METER(w/o DPF)  INSPECTION  


PROCEDURE

Hide 1.INSPECT MASS AIR FLOW METER

a.

Check the output voltage.

i.
A165594E06
2.427,2.844 2.156,3.219 false 2.594,2.792 2.729,2.188 false 2.74,2.854 3.104,3.396 false 0.24,3.646 0.49,3.854 0.25,0.208 10 false Air 2.906,3.417 3.385,3.604 0.479,0.188 10 false 1 (+B) 2.75,2 3.354,2.229 0.604,0.229 10 false 2 (E2G) 1.823,3.24 2.323,3.438 0.5,0.198 10 false 3 (VG) 0.146,0.177 2.667,0.594 2.521,0.417 10 false Component without harness connected: (MAF Meter)

Apply battery voltage across terminals 1 (+B) and 2 (E2G).

NOTICE:

While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



ii.

Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG), and negative (-) tester probe to terminal 2 (E2G).


iii.

Blow air into the MAF meter, and check that the voltage fluctuates.

If the result is not as specified, replace the MAF meter.



b.
A165595E01
1.944,1.488 2.834,1.902 0.891,0.414 10 Platinum Hot Wire (Heater) 1.312,2.466 1.838,1.625 false 1.838,1.625 1.915,1.625 false

Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.

OK:

There is no foreign material.


If the result is not as specified, replace the mass air flow meter.


c.

Check the IAT sensor.

A385316E01
1.823,1.604 2.115,1.104 2.115,1.104 2.271,1.104 true 1.708,1.604 1.49,1.104 1.49,1.104 1.313,1.104 true 1.823,1.667 2,1.99 2,1.99 2.146,1.99 true 1.708,1.677 1.604,2.01 1.604,2.01 1.417,2.01 true 5.49,1.125 5.875,0.906 false 0.323,0.177 2.802,0.552 2.479,0.375 10 false Component without harness connected: (MAF Meter) 2.344,1.01 2.5,1.208 0.156,0.198 10 false 4 1.167,1.021 1.323,1.219 0.156,0.198 10 false 5 2.208,1.896 2.583,2.083 0.375,0.188 10 false THA 1.156,1.906 1.438,2.094 0.281,0.188 10 false E2 3.135,0.063 4.167,0.24 1.031,0.177 10 false Resistance kΩ 4.146,0.104 4.385,0.313 0.24,0.208 10 false 20 4.135,0.365 4.375,0.573 0.24,0.208 10 false 10 4.104,2.115 4.385,2.323 0.281,0.208 10 false 0.1 4.104,1.844 4.385,2.052 0.281,0.208 10 false 0.2 4.104,1.688 4.385,1.896 0.281,0.208 10 false 0.3 4.104,1.5 4.385,1.708 0.281,0.208 10 false 0.5 4.208,1.208 4.375,1.417 0.167,0.208 10 false 1 4.219,0.99 4.385,1.198 0.167,0.208 10 false 2 4.208,0.833 4.375,1.042 0.167,0.208 10 false 3 4.208,0.646 4.375,0.854 0.167,0.208 10 false 5 4.49,2.365 4.771,2.573 0.281,0.208 10 false -20 4.885,2.365 5.167,2.573 0.281,0.208 10 false 0 5.188,2.375 5.469,2.583 0.281,0.208 10 false 20 5.531,2.365 5.813,2.573 0.281,0.208 10 false 40 5.844,2.365 6.125,2.573 0.281,0.208 10 false 60 6.188,2.365 6.469,2.573 0.281,0.208 10 false 80 6.49,2.375 6.771,2.583 0.281,0.208 10 false 100 4.5,2.531 4.781,2.74 0.281,0.208 10 false (-4) 4.813,2.51 5.094,2.719 0.281,0.208 10 false (32) 5.146,2.51 5.427,2.719 0.281,0.208 10 false (68) 5.448,2.51 5.792,2.729 0.344,0.219 10 false (104) 5.792,2.51 6.135,2.729 0.344,0.219 10 false (140) 6.125,2.51 6.469,2.729 0.344,0.219 10 false (176) 6.479,2.51 6.865,2.708 0.385,0.198 10 false (212) 5.948,0.792 6.76,0.99 0.813,0.198 10 false Acceptable 3.073,2.354 4.458,2.583 1.385,0.229 10 false Temperature °C (°F)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (THA) - 5 (E2) -20°C (-4°F) 12.5 to 16.9 kΩ
20°C (68°F) 2.19 to 2.67 kΩ
60°C (140°F) 0.5 to 0.68 kΩ


If the result is not as specified, replace the MAF meter.