Home › Engine / Hybrid System › 1VD-FTV (ENGINE CONTROL) › ENGINE COOLANT TEMPERATURE SENSOR
RM2660E _51 Engine / Hybrid System _052773 1VD-FTV ENGINE CONTROL _0254988 ENGINE COOLANT TEMPERATURE SENSOR G

1VD-FTV ENGINE CONTROL  ENGINE COOLANT TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 89422C 1.INSPECT ENGINE COOLANT TEMPERATURE SENSOR

A184884E03
1.125,1.552 1.333,1.365 1.333,1.365 1.438,1.365 false 5.927,0.573 5.802,0.573 5.802,0.573 5.448,0.927 false 1.031,1.563 0.823,1.375 0.823,1.375 0.719,1.375 false 3.385,0.042 4.406,0.25 1.021,0.208 10 false Resistance kΩ 5.979,0.5 6.99,0.729 1.01,0.229 10 false Acceptable 4.604,0.125 4.813,0.292 0.208,0.167 8 false 20 4.594,0.365 4.802,0.542 0.208,0.177 8 false 10 4.646,0.75 4.781,0.917 0.135,0.167 8 false 3 4.646,0.948 4.781,1.104 0.135,0.156 8 false 2 4.635,1.188 4.802,1.333 0.167,0.146 8 false 1 4.594,1.802 4.917,2.01 0.323,0.208 8 false 0.2 4.594,1.677 4.917,1.885 0.323,0.208 8 false 0.3 4.594,1.438 4.917,1.646 0.323,0.208 8 false 0.5 4.604,2 4.927,2.208 0.323,0.208 8 false 0.1 5.135,2.292 5.365,2.615 0.229,0.323 8 false 0 5.354,2.292 5.552,2.479 0.198,0.188 8 false 20 5.594,2.292 5.802,2.469 0.208,0.177 8 false 40 5.854,2.292 6.063,2.458 0.208,0.167 8 false 60 6.094,2.292 6.313,2.49 0.219,0.198 8 false 80 6.302,2.302 6.573,2.469 0.271,0.167 8 false 100 4.833,2.281 5.073,2.458 0.24,0.177 8 false -20 3.219,2.208 4.698,2.438 1.479,0.229 10 false Temperature °C (°F) 0.563,1.24 0.688,1.427 0.125,0.188 10 false 1 1.479,1.271 1.625,1.448 0.146,0.177 10 false 2 0.146,0.083 2.667,0.427 2.521,0.344 10 false Component without harness connected: (Engine Coolant Temperature Sensor) 4.833,2.417 5.083,2.573 0.25,0.156 8 false (-4) 5.052,2.417 5.323,2.583 0.271,0.167 8 false (32) 5.313,2.417 5.583,2.583 0.271,0.167 8 false (68) 5.531,2.417 5.854,2.573 0.323,0.156 8 false (104) 5.813,2.406 6.146,2.583 0.333,0.177 8 false (140) 6.396,2.406 6.75,2.583 0.354,0.177 8 false (212) 6.083,2.406 6.438,2.583 0.354,0.177 8 false (176)

a.

Partially immerse the sensor in water and warm up the water.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 Approximately 20°C (68°F) 2.32 to 2.59 kΩ
1 - 2 Approximately 80°C (176°F) 0.310 to 0.326 kΩ


If the result is not as specified, replace the sensor.

NOTICE:

When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.