Home › Engine / Hybrid System › 1VD-FTV (ENGINE CONTROL) › INTAKE AIR TEMPERATURE SENSOR
RM2660E _51 Engine / Hybrid System _052773 1VD-FTV ENGINE CONTROL _0254989 INTAKE AIR TEMPERATURE SENSOR G

1VD-FTV ENGINE CONTROL  INTAKE AIR TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 89424D 1.INSPECT INTAKE AIR TEMPERATURE SENSOR

A164295E08
5.563,2.177 5.865,1.802 false 3.385,1.021 4.594,1.302 1.208,0.281 10 false Resistance kΩ 5.99,1.604 7,1.833 1.01,0.229 10 false Acceptable 4.583,1.094 4.792,1.26 0.208,0.167 8 false 30 4.594,1.281 4.802,1.469 0.208,0.188 8 false 20 4.583,1.5 4.781,1.677 0.198,0.177 8 false 10 4.625,1.76 4.76,1.927 0.135,0.167 8 false 5 4.625,1.906 4.781,2.052 0.156,0.146 8 false 3 4.625,2.063 4.792,2.229 0.167,0.167 8 false 2 4.625,2.271 4.792,2.406 0.167,0.135 8 false 1 4.563,2.813 4.802,2.979 0.24,0.167 8 false 0.2 4.573,2.677 4.802,2.833 0.229,0.156 8 false 0.3 4.573,2.51 4.813,2.646 0.24,0.135 8 false 0.5 4.573,3.01 4.833,3.188 0.26,0.177 8 false 0.1 5.135,3.313 5.292,3.479 0.156,0.167 8 false 0 5.354,3.313 5.542,3.479 0.188,0.167 8 false 20 5.583,3.313 5.792,3.469 0.208,0.156 8 false 40 5.833,3.323 6.042,3.479 0.208,0.156 8 false 60 6.094,3.323 6.313,3.479 0.219,0.156 8 false 80 6.406,3.313 6.698,3.49 0.292,0.177 8 false 100 4.844,3.313 5.052,3.479 0.208,0.167 8 false -20 3.229,3.24 4.708,3.469 1.479,0.229 10 false Temperature °C (°F) 0.75,0.063 3.229,0.458 2.479,0.396 10 false Component without harness connected: (Intake Air Temperature Sensor) 1.938,1.198 2.104,1.396 0.167,0.198 10 false 2 2.188,1.198 2.365,1.396 0.177,0.198 10 false 1 4.823,3.448 5.104,3.604 0.281,0.156 8 false (-4) 5.052,3.448 5.333,3.625 0.281,0.177 8 false (32) 5.292,3.448 5.615,3.625 0.323,0.177 8 false (68) 5.51,3.438 5.854,3.615 0.344,0.177 8 false (104) 5.781,3.448 6.125,3.635 0.344,0.188 8 false (140) 6.063,3.438 6.427,3.615 0.365,0.177 8 false (176) 6.375,3.427 6.698,3.615 0.323,0.188 8 false (212)

a.

Partially immerse the sensor in water and warm up the water.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 Approximately 20°C (68°F) 2.21 to 2.65 kΩ
1 - 2 Approximately 60°C (140°F) 0.55 to 0.61 kΩ


If the result is not as specified, replace the sensor.

NOTICE:

When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.