Home › Engine / Hybrid System › 3UR-FE (ENGINE CONTROL) › ENGINE COOLANT TEMPERATURE SENSOR
RM2660E _51 Engine / Hybrid System _052775 3UR-FE ENGINE CONTROL _0255026 ENGINE COOLANT TEMPERATURE SENSOR G

3UR-FE ENGINE CONTROL  ENGINE COOLANT TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 89422 1.INSPECT ENGINE COOLANT TEMPERATURE SENSOR

A204844E25
5.563,1.146 5.854,0.667 5.854,0.667 5.948,0.667 false 4.156,0.115 4.365,0.365 0.208,0.25 10 false *1 5.99,0.573 6.24,0.823 0.25,0.25 10 false *3 6.615,2.271 7.115,2.448 0.5,0.177 10 false °C (°F) 4.625,0.125 4.948,0.333 0.323,0.208 8 false 30 4.625,0.25 4.948,0.458 0.323,0.208 8 false 20 4.625,0.458 4.948,0.667 0.323,0.208 8 false 10 4.625,0.708 4.948,0.917 0.323,0.208 8 false 5 4.625,0.865 4.948,1.073 0.323,0.208 8 false 3 4.625,1.042 4.948,1.25 0.323,0.208 8 false 2 4.625,1.229 4.948,1.438 0.323,0.208 8 false 1 4.625,1.76 4.948,1.969 0.323,0.208 8 false 0.2 4.625,1.635 4.948,1.844 0.323,0.208 8 false 0.3 4.625,1.49 4.948,1.698 0.323,0.208 8 false 0.5 4.625,1.99 4.948,2.198 0.323,0.208 8 false 0.1 5.156,2.281 5.302,2.458 0.146,0.177 8 false 0 5.365,2.281 5.552,2.469 0.188,0.188 8 false 20 5.604,2.281 5.781,2.469 0.177,0.188 8 false 40 5.854,2.281 6.031,2.448 0.177,0.167 8 false 60 6.115,2.281 6.281,2.438 0.167,0.156 8 false 80 6.333,2.281 6.583,2.448 0.25,0.167 8 false 100 4.854,2.281 5.073,2.458 0.219,0.177 8 false -20 4.573,2.281 4.802,2.51 0.229,0.229 10 false *2 4.854,2.448 5.063,2.656 0.208,0.208 8 false (-4) 5.083,2.448 5.344,2.646 0.26,0.198 8 false (32) 5.323,2.448 5.573,2.656 0.25,0.208 8 false (68) 5.542,2.448 5.854,2.625 0.313,0.177 8 false (104) 5.823,2.448 6.125,2.635 0.302,0.188 8 false (140) 6.104,2.448 6.417,2.646 0.313,0.198 8 false (176) 6.385,2.448 6.698,2.635 0.313,0.188 8 false (212) 4.604,0 4.865,0.156 0.26,0.156 10 false kΩ

Text in Illustration
*1 Resistance kΩ *2 Temperature °C (°F)
*3 Acceptable Range - -

a.

Partially immerse the sensor in water and warm up the water.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 Approximately 20°C (68°F) 2.32 to 2.59 kΩ
1 - 2 Approximately 80°C (176°F) 0.310 to 0.326 kΩ


NOTICE:

When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.


If the result is not as specified, replace the sensor.