Home › Engine / Hybrid System › 1GR-FE (FUEL) › FUEL PUMP(for Double Tank Type)
RM2660E _51 Engine / Hybrid System _052780 1GR-FE FUEL _0255079 FUEL PUMP(for Double Tank Type) G

1GR-FE FUEL  FUEL PUMP(for Double Tank Type)  INSPECTION  


PROCEDURE

Hide 23221 1.INSPECT FUEL PUMP

A158976E03
2.579,1.968 2.699,2.128 0.120,0.160 10 1 0.812,1.977 0.919,2.121 0.107,0.144 10 2 0.083,0.075 2.561,0.423 2.478,0.349 10 Component without harness connected: (Fuel Pump) 1.413,2.055 0.947,2.055 false 2.547,2.059 2.081,2.059 false

a.

Inspect the resistance of the fuel pump.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.2 to 3.0 Ω


If the result is not as specified, replace the fuel pump.



b.
A181451E01
0.081,0.095 2.558,0.444 2.477,0.349 10 Component without harness connected: (Fuel Pump) 2.559,1.524 2.673,1.671 0.114,0.147 10 1 0.829,1.534 0.943,1.681 0.114,0.147 10 2 2.539,1.621 2.397,1.621 2.397,1.621 2.027,2.164 false 0.959,1.627 1.101,1.627 1.101,1.627 1.47,2.17 false

Inspect the operation of the fuel pump.

i.

Connect the battery's positive (+) lead to terminal 1 of the connector, and the negative (-) lead to terminal 2. Check that the fuel pump operates.

If the result is not as specified, replace the fuel pump and fuel pump ECU.

NOTICE:
·

These tests must be performed within 10 seconds to prevent the coil from burning out.


·

Keep the fuel pump as far away from the battery as possible.


·

Always turn the voltage on and off on the battery side, not the fuel pump side.

·

When the pump is locked and does not operate due to foreign matter being stuck, etc., replace the fuel pump ECU together with the fuel pump, as the fuel pump ECU may be damaged electrically.