Home › Engine / Hybrid System › 1GR-FE (EMISSION CONTROL) › CANISTER › 2014.08–2015.08
RM2660E _51 Engine / Hybrid System _052784 1GR-FE EMISSION CONTROL _0255123 CANISTER G

1GR-FE EMISSION CONTROL  CANISTER  INSPECTION  


PROCEDURE

Hide 77740 1.INSPECT CHARCOAL CANISTER

a.
A179221E03
0.667,1.885 0.729,1.885 0.729,1.885 1,1.427 false 1.042,0.198 1.146,0.198 1.146,0.198 1.563,1.021 false 2.865,1.094 2.698,1.094 2.698,1.094 1.719,1.583 false 0.26,1.396 0.49,1.583 0.229,0.188 10 false Air 0.146,1.792 0.583,1.969 0.438,0.177 10 false Port A 2.896,1.01 3.344,1.188 0.448,0.177 10 false Port B 0.563,0.115 1.031,0.292 0.469,0.177 10 false Port C

Visually check the canister for cracks or damage.


b.

Blow compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A and check that air flows without resistance from port B and port C.

If the result is not as specified, replace the canister.


c.

Apply a vacuum of 1.96 kPa (20 gf/cm2, 0.28 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that air flows when port B is opened.

If the result is not as specified, replace the canister.


Hide 77740 2.CLEAN FILTER IN CANISTER

a.
A179222E03
0.677,1.875 0.75,1.875 0.75,1.875 0.979,1.458 true 2.875,1.094 2.646,1.094 2.646,1.094 1.698,1.594 true 0.219,1.396 0.458,1.573 0.24,0.177 10 false Air 0.146,1.781 0.604,1.958 0.458,0.177 10 false Port A 2.927,1.021 3.385,1.198 0.458,0.177 10 true Port B

Clean the filter by blowing compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A while holding port B closed.

NOTICE:

Do not attempt to wash the canister.