Home › Engine / Hybrid System › 1GR-FE (EMISSION CONTROL) › CANISTER(w/o Secondary Air Injection System) › from 2015.08
RM2660E _51 Engine / Hybrid System _052784 1GR-FE EMISSION CONTROL _0255134 CANISTER(w/o Secondary Air Injection System) G

1GR-FE EMISSION CONTROL  CANISTER(w/o Secondary Air Injection System)  INSPECTION  


PROCEDURE

Hide 77740 1.INSPECT CANISTER

a.
A365874E04
1.198,1.156 0.74,1.615 0.74,1.615 0.594,1.615 true 1.917,0.625 2.063,0.219 2.063,0.219 2.177,0.219 false 2.208,1.438 1.938,1.813 1.938,1.813 1.802,1.813 true 0.385,1.531 0.542,1.708 0.156,0.177 10 false *a 2.219,0.115 2.375,0.292 0.156,0.177 10 false *c 1.583,1.719 1.74,1.896 0.156,0.177 10 false *b

Visually check the canister for cracks or damage.

Text in Illustration
*a Port A
*b Port B
*c Port C
V100135

Air


b.

Blow compressed air of 4.9 kPa (0.05 kgf/cm2, 0.7 psi) into port A and check that air flows without resistance from port B and port C.

If the result is not as specified, replace the canister.


c.

Apply a vacuum of 1.96 kPa (15 mmHg, 0.579 in.Hg) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that air flows when port B is opened.

If the result is not as specified, replace the canister.


Hide 77740 2.CLEAN FILTER IN CANISTER

a.
A365875E01
0.54,1.338 0.695,1.519 0.156,0.181 10 *a 2.943,0.53 3.099,0.711 0.156,0.181 10 *b 1.199,1.105 0.857,1.447 0.857,1.447 0.751,1.447 false 2.223,1.315 2.802,0.636 2.802,0.636 2.899,0.636 false

Clean the filter by blowing compressed air of 4.9 kPa (0.05 kgf/cm2, 0.7 psi) into port A while holding port B closed.

Text in Illustration
*a Port A
*b Port B
V100135

Air

NOTICE:

Do not attempt to wash the canister.