17610C
1.INSPECT AIR PUMP ASSEMBLY (w/ Heater)
Check the heater resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (APH+) - 3 (APHG) | -20°C (-4°F) | 4.4 to 20.0 Ω |
| -10°C (14°F) | 3.9 to 18.0 Ω | |
| 0°C (32°F) | 3.5 to 16.0 Ω | |
| 10°C (50°F) | 3.2 to 15.0 Ω | |
| 20°C (68°F) | 3.0 to 14.0 Ω |
| *a | Component without harness connected
(Air Pump) |
If the result is not as specified, replace the air pump assembly.