1UR-FE EMISSION CONTROL  AIR SWITCHING VALVE(for Bank 1)  INSPECTION  


PROCEDURE

Hide 25710 1.INSPECT AIR SWITCHING VALVE ASSEMBLY

a.
A266183E04
0.188,0.25 0.365,0.427 0.177,0.177 10 false *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 5 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground Always 1 MΩ or higher
5 - Body ground


Text in Illustration
*a Component without harness connected
(Air Switching Valve)

NOTICE:

When measuring the resistance, do not touch terminals 2, 3 or 4.


HINT:

When measuring the resistance, make sure that the surface temperature of the air switching valve assembly is 20°C (68°F).


If the result is not as specified, replace the air switching valve assembly.


b.
A266184E05
1.885,2.906 2.094,2.906 2.094,2.906 2.583,2.229 false 0.5,1.052 0.667,1.052 0.667,1.052 0.896,1.729 false 1.688,2.813 1.865,3 0.177,0.188 10 false *1 0.313,0.969 0.5,1.146 0.188,0.177 10 false *2

Check the operation of the air switching valve.

i.

Check that air does not flow from port A to port B.

Text in Illustration
*1 Port A
*2 Port B
V100135

Air

NOTICE:

Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.


If the result is not as specified, replace the air switching valve assembly.


ii.
A266185E05
2.229,4.271 2.365,4.271 2.365,4.271 2.635,3.854 false 0.646,2.781 0.792,2.781 0.792,2.781 0.99,3.396 false 0.188,0.24 0.396,0.448 0.208,0.208 10 false *a 2.042,4.188 2.208,4.354 0.167,0.167 10 false *1 0.458,2.708 0.635,2.896 0.177,0.188 10 false *2

Apply battery voltage across terminals 1 and 5.

Text in Illustration
*1 Port A
*2 Port B
*a Component without harness connected
(Air Switching Valve)
V100135

Air

NOTICE:

When applying voltage, do not touch terminals 2, 3 or 4.



iii.

Check that air flows from port A to port B.

If the result is not as specified, replace the air switching valve assembly.