1.INSPECT DPF SWITCH ASSEMBLY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 - 4 | Switch OFF | 10 kΩ or higher |
| 1 - 4 | Switch ON | Below 1 Ω |
If the result is not as specified, replace the DPF switch assembly.
Apply battery voltage to the switch connector and check that the DPF switch illuminates.
| Measurement Condition | Specified Condition |
|---|---|
| Apply battery voltage to terminal 3 (+) and 2 (-) | Mark illumination illuminates |
If the result is not as specified, replace the DPF switch assembly.