Home › Engine / Hybrid System › 3UR-FE (EMISSION CONTROL) › CANISTER › 2014.08–2015.08
RM2660E _51 Engine / Hybrid System _052787 3UR-FE EMISSION CONTROL _0255159 CANISTER G

3UR-FE EMISSION CONTROL  CANISTER  INSPECTION  


PROCEDURE

Hide 77740 1.INSPECT CANISTER

a.
A179221E04
0.667,1.885 0.729,1.885 0.729,1.885 1,1.427 false 1.042,0.198 1.146,0.198 1.146,0.198 1.563,1.021 false 2.865,1.094 2.698,1.094 2.698,1.094 1.719,1.583 false 0.469,1.802 0.635,1.979 0.167,0.177 10 false *1 2.896,1.01 3.115,1.177 0.219,0.167 10 false *2 0.813,0.104 1.01,0.302 0.198,0.198 10 false *3

Visually check the canister for cracks or damage.

Text in Illustration
*1 Port A
*2 Port B
*3 Port C
V100135

Air


b.

Blow compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A and check that air flows without resistance from port B and port C.

If the result is not as specified, replace the canister.


c.

Apply a vacuum of 1.96 kPa (20 gf/cm2, 0.28 psi) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that air flows when port B is opened.

If the result is not as specified, replace the canister.


Hide 77740 2.CLEAN FILTER IN CANISTER

a.
A179222E04
0.656,1.865 0.729,1.865 0.729,1.865 0.958,1.448 true 2.875,1.115 2.646,1.115 2.646,1.115 1.698,1.615 true 0.479,1.771 0.656,1.969 0.177,0.198 10 false *1 2.927,1.042 3.156,1.219 0.229,0.177 10 false *2

Clean the filter by blowing compressed air of 4.9 kPa (50 gf/cm2, 0.71 psi) into port A while holding port B closed.

Text in Illustration
*1 Port A
*2 Port B
V100135

Air

NOTICE:

Do not attempt to wash the canister.