17650
1.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
Disconnect the vacuum switching valve connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 37 to 44 Ω |
| 1 - Body ground | Always | 1 MΩ or higher |
| 2 - Body ground |
If the result is not as specified, replace the vacuum switching valve assembly.
Check the vacuum switching valve operation.
When applying a vacuum to port E, check that air is sucked into the filter.
| *1 | Filter |
| *a | Vacuum |
| *b | Air |
Apply battery voltage to the connector, and check the VSV operation.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2 |
Air is sucked into port E when a vacuum is applied to port F |
| *a | Vacuum |
| *b | Air |
If the result is not as specified, replace the vacuum switching valve assembly.
Connect the vacuum switching valve connector.