Home › Engine / Hybrid System › 1GR-FE (COOLING) › THERMOSTAT
RM2660E _51 Engine / Hybrid System _052792 1GR-FE COOLING _0255185 THERMOSTAT G

1GR-FE COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16031 1.INSPECT WATER INLET WITH THERMOSTAT

HINT:
A174313

The valve opening temperature is inscribed on the thermostat.


a.
A134799

Immerse the thermostat in water, then gradually heat the water.


b.

Check the valve opening temperature of the thermostat.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)


If the valve opening temperature is not as specified, replace the water inlet with thermostat.


c.
A174314E01
2.245,1.599 2.905,1.773 0.660,0.174 10 Valve Lift

Check the valve lift.

Standard valve lift:

8.0 mm (0.315 in.) or more at 95°C (203°F)


If the valve lift is not as specified, replace the water inlet with thermostat.


d.

Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)).

If not fully closed, replace the thermostat.