Home › Engine / Hybrid System › 1GR-FE (COOLING) › RADIATOR
RM2660E _51 Engine / Hybrid System _052792 1GR-FE COOLING _0255186 RADIATOR G

1GR-FE COOLING  RADIATOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 16401 1.INSPECT RADIATOR CAP SUB-ASSEMBLY

CAUTION:

Do not remove the radiator reservoir cap while the engine and radiator are still hot. Pressurized, hot engine coolant and steam may be released and cause serious burns.


A110260

a.

Measure the valve opening pressure.

i.

If there are water stains or foreign matter on rubber packing 1, 2 or 3, clean it by using water and finger scouring.


ii.

Check that rubber packing 1, 2 and 3 are not deformed, cracked or swollen.


iii.

Check that rubber packing 3 and 4 are not stuck together.


iv.

Apply engine coolant to rubber packing 2 and 3.


v.
A380707E03
0.438,0.979 0.333,1.583 0.333,1.583 0.333,1.667 false 1.479,0.771 1.792,0.146 1.792,0.146 1.885,0.146 false 1.385,1.417 2.333,1.667 0.948,0.25 10 true 30° or Higher 0.042,1.667 1.875,1.865 1.833,0.198 10 false Radiator Cap 1.938,0.063 3.198,0.313 1.26,0.25 10 false Radiator Cap Tester

Prepare a radiator cap tester, and tilt it more than 30°.


vi.

Pump the cap tester several times, and check the maximum pressure*.

Pumping speed:

1 pump per second


HINT:

*: Even if the cap cannot maintain the maximum pressure, it is not a defect.


Standard Judgment Criterion:
Item Specified Condition
Standard value
(for brand-new cap)
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi)
Minimum standard value
(after using cap)
79 kPa (0.8 kgf/cm2, 11.4 psi)


If the maximum pressure is less than the minimum standard value, replace the radiator cap sub-assembly.



Hide 16400 2.INSPECT FINS FOR BLOCKAGE

a.

Check that the fins of the radiator core are not blocked with leaves, dirt, or insects.

If the fins are blocked, wash them with water or a steam cleaner.

NOTICE:
·

If the distance between the steam cleaner and core is too close, the fins may be damaged.

·

Keep the following injection distance.

Standard Injection Distance:
Injection Distance Injection Pressure
300 mm (11.8 in.) 2942 to 4903 kPa (30.0 to 50.0 kgf/cm2, 427 to 711 psi)
500 mm (19.7 in.) 4903 to 7845 kPa (50.0 to 80.0 kgf/cm2, 711 to 1138 psi)


·

If the fins are bent, straighten them with a screwdriver or pliers.

·

Never apply water directly onto the electric components.




b.

Dry the fins with compressed air.